■ Types of data output

Use the Mitutoyo Input Tool (available for pur-
chase from many dealers) to transfer measurement
data to a computer.
• Model: IT-005D 264-005 (For any standard Win-
dows computer)
Connection cable NO.937244 2 m (sold sepa-
rately)
(Please contact Mitutoyo Corporation or a Mitutoyo
dealer about purchasing these items.)
■ Types of analog data output
An analog cord is available for separate purchase
(1.5 m, item HP-8060). This cable can be used to
connect a pen recorder, oscilloscope or voltmeter
to the HIOS torque meter. When using these instru-
ments, read their operation manuals to insure cor-
rect operation.

■ Customer service

• Repair
1. Service charges will be made for repairs under
the following circumstances:
(1) Malfunctioning or damage caused by incor-
rect use of the instrument, the instrument has
been disassembled or it malfunctions due to
attempted repair.
(2) Oil has been added to the sensor unit,
switches or inside the instrument.
(3) The instrument has been damaged during
shipping, by dropping, etc.
(4) Damage due to fire, exposure to gas, earth-
quake, water, irregular power supply or
other type of disaster.
(5) Service charges will also be made for cali-
bration, inspection or parts replacement.
2. No charge will be made for service in the case
of inspection and/or calibration of the same part
that becomes necessary within three months after
inspection or calibration has been performed.
(This does not apply under circumstances (1) − (4)
above.)
• Shipping and handling charges incurred for re-
pair service must be paid by the customer. Please
direct questions about customer services to HIOS
Corporation or your HIOS dealer.
■ Attention
The product that you have purchased contains a
rechargeable battery. The battery is recyclable. At
the end of it's useful life, under various state and
local laws, it may be illegal to dispose of this bat-
tery into the municipal waste stream. Check with
your local solid waste officials for details in your
area for recycling options or proper disposal.
■ Inspections and calibration
HIOS torque meters employ a unique sensor mech-
anism that maintains accuracy for long periods. We
recommend that the torque meter be sent in to HIOS
Corporation for inspection at least once a year. (Note
that a fee is charged for this service.)
HIOS torque meters are shipped calibrated to meet
our accuracy standards. Depending on the condi-
tions under which the meter is used, accuracy may
be affected over the course of months or years.
Therefore, HIOS offers calibration and, when nec-
essary, overhaul services. We also recommend use
of the periodic calibration documentation included
with the torque meter. This documentation shows
the relation of the HIOS standards to Japan's stan-
dards.
■ Cautions to be observed when
sending the torque meter in for
calibration or repair
1. Pack the meter in the attache case in which it
was originally shipped to protect it from violent
impacts during shipping.
2. Do not put anything into the attache case other
than the items originally shipped inside. Never
include items such as homemade mounting
plates, tools or extra bits. HIOS cannot assume
responsibility for these.
3. Please explain the nature of the difficulty with
the instrument in sufficient detail.