System Storage EXP5060 Quick Start Guide
This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM
System Storage
EXP5060 storage expansion enclosure.

Related documentation

For detailed information about the storage expansion enclosure, see the IBM System Storage EXP5060
Storage Expansion Enclosure Installation, User's, and Maintenance Guide. For safety information, see the
multilingual IBM Safety Information document on the Documentation CD.
For more information about how to use a lift tool to install the storage expansion enclosure, see the
documentation that came with your lift tool.
For educational information about the EXP5060 and other IBM System Storage products, go to
http://ibmdsseriestraining.com/. For the latest information about IBM System Storage disk storage
systems, go to http://www.ibm.com/systems/support/storage/disk.

Installation overview

The installation of the storage expansion enclosure involves the following procedures:
1. "Installation guidelines"

Installation guidelines

Before you install the storage expansion enclosure in a rack cabinet, review the following guidelines:
v This product is to be installed and serviced only by qualified IBM service representatives.
v Because of the size and weight of the storage enclosure as shipped, a lift tool and a minimum of two
trained service technicians are required to push the enclosure out of its custom-designed package and
onto the lift tool.
v The storage expansion enclosure must not be installed in a rack position where the top of the unit is
above 32U or the bottom of the unit is above the 29U mark on the rack cabinet.
v Make sure that the room air temperature is below 25°C (77°F). The operating temperature for optimal
performance is 22°C (72°F) or lower.
v Do not block any air vents; usually 15 cm (6 in.) of space provides proper airflow.
®

Advertisement

Table of Contents
loading

Summary of Contents for IBM EXP5060

  • Page 1: Table Of Contents

    System Storage EXP5060 Quick Start Guide ® This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM ™ System Storage EXP5060 storage expansion enclosure. Related documentation For detailed information about the storage expansion enclosure, see the IBM System Storage EXP5060 Storage Expansion Enclosure Installation, User’s, and Maintenance Guide.
  • Page 2 200 V - 240 V input sources. In addition, you might need to purchase a special cable for the rack PDUs for the voltage and currents that the EXP5060 requires. If you do not have an IBM System Storage 2101-200 rack with the supported PDUs and 60 A power cords, check your PDUs or input sources to make sure that they can handle the EXP5060 voltage and currents.
  • Page 3: Ordering The Lift Tool

    Ordering the lift tool The use of a lift tool is required when you install an EXP5060 in a rack cabinet and when you remove the EXP5060 from a rack cabinet. Make sure that the lift tool is available on location at the time of the installation.
  • Page 4: Unpacking The Shipping Box

    The disk drive modules (DDMs) that come with the storage expansion enclosure are packaged in a smaller box inside the shipping box. To unpack the shipping box, complete the following steps: 1. Remove the following items from the shipping box. Do not remove the EXP5060 from the shipping box at this time.
  • Page 5: Inventory List

    If any items are missing or damaged, contact your place of purchase. Notes: 1. The illustration might differ slightly from your hardware. 2. Depending on your EXP5060 order, your shipping box might contain additional materials that are not shown in the following illustration. assembly (2)
  • Page 6 – ESMs (2) v Handles (4), packaged in a smaller box inside the shipping box v DDMs (20 or more, depending on your EXP5060 order), packaged in a smaller box inside the shipping v Bezel (1) v Fibre Channel signal cables (2 or more, depending on your EXP5060 order)
  • Page 7: Installing The Support Rails And Rear Brackets

    If the support rails will be installed above an existing storage subsystem or storage expansion enclosure, position the EXP5060 support rails directly above it. If the support rails will be installed below an existing storage subsystem or storage expansion enclosure, allow 178 mm (7 in.) of vertical clearance for the EXP5060.
  • Page 8 Attention: Make sure that the screws are tight enough to support the weight of the storage expansion enclosure, but do not completely tighten the screws yet. 7. Make sure that the holes in the rail above and below the top mounting screw are visible through the holes of the rack flange and tighten the two M5 screws to secure the front of the rail to the rack flange.
  • Page 9: Installing And Removing The Handles

    Installing and removing the handles Install the handles on the storage expansion enclosure before you move the unit onto the lift tool. After you install the storage expansion enclosure in the rack cabinet and remove the handles, store the handles for future use.
  • Page 10: Installing The Storage Expansion Enclosure In The Rack Cabinet

    “Component weights”, in the IBM System Storage EXP5060 Storage Subsystem Installation, User’s, and Maintenance Guide for additional information. b. Before you move or relocate a rack that contains EXP5060 storage expansion enclosures, see “Relocating a populated rack” in the IBM System Storage EXP5060 Storage Subsystem Installation, User’s, and Maintenance Guide for additional information.
  • Page 11 Rear Front 6. Install and tighten two M5 screws on each side of the rack, above and below the top M5 screws, in the front of the storage expansion enclosure to secure the storage expansion enclosure chassis to the rack flanges. 7.
  • Page 12: Installing The Ddms

    Important: The installation order within each drawer is from left to right in each row if you are facing the front of the EXP5060. You must install DDMs in slots 1, 4, 7, and 10. Make sure that the four DDMs in each row are adjacent to each other. The long edge of each DDM should touch the DDM next to it.
  • Page 13 Latch Raised buttons Slots 4. Align the raised buttons on the sides with the matching slots in the DDM channel on the drawer. Lower the DDM down onto the drawer, and rotate the DDM handle until the DDM snaps into place under the DDM release lever.
  • Page 14: Installing The Cables

    DS5100 and DS5300 Installation, User’s, and Maintenance Guide. The EXP5060 is compatible with DS5100 and DS5300 storage subsystems. The following cabling instructions are shown with the assumption that the EXP5060 will be connected to a DS5100 or DS5300 storage subsystem.
  • Page 15 To cable two storage expansion enclosures to a storage subsystem, complete the following steps: 1. The Small Form-factor Pluggable transceivers (SFPs) are preinstalled in the Fibre Channel host ports in the storage subsystem and the EXP5060. Make sure the SFPs are seated completely in the host ports.
  • Page 16 5. Connect a fiber-optic cable from drive port 3 on controller B in the storage subsystem to port 1B on ESM B in EXP5060 two. Note: For more information about cabling configurations, see the IBM System Storage EXP5060 Installation, User’s, and Maintenance Guide that came with the storage expansion enclosure.
  • Page 17 To cable two storage expansion enclosures to a storage subsystem with drive-side trunking, complete the following steps: 1. The Small Form-factor Pluggable transceivers (SFPs) are preinstalled in the Fibre Channel host ports in the storage subsystem and the EXP5060. Make sure the SFPs are seated completely in the host ports.
  • Page 18 9. Connect a fiber-optic cable from drive port 4 on controller B in the storage subsystem to port 2B on ESM B in EXP5060 two. Note: For more information about cabling configurations, see the IBM System Storage EXP5060 Installation, User’s, and Maintenance Guide that came with the storage expansion enclosure.
  • Page 19: Turning On The Power

    PDUs for the voltage and currents that the EXP5060 requires. If you do not have an IBM System Storage 2101-200 rack with the supported PDUs and 60 A power cords, check your PDUs or input sources to make sure that they can handle the EXP5060 voltage and currents.
  • Page 20: Installing The Software

    Obtaining information from the IBM Support Web site The IBM System Storage documentation that is described in this Quick Start Guide and other IBM System Storage information is on the IBM support Web site. To access the latest documentation, downloads, and other technical updates on the IBM support Web site, complete the following steps.
  • Page 21 Install second Install second Install first Install first Install second Install second FRONT Rack Mounting Template Rail assembly Rail assembly (front left) (front right) Install first Install first...
  • Page 23 Rear bracket Rear bracket REAR Rack Mounting Template Rail assembly Rail assembly (rear left) (rear right) Rail mounting guide ® Printed in the U.S.A...
  • Page 24 First Edition (October 2009) Printed in the U.S.A. IBM and System Storage are trademarks of the IBM Corporation in the United States, other countries, or both. ® ® Microsoft and Windows are trademarks of Microsoft Corporation in the United States, other countries, or both.

Table of Contents