A-1
TECHNICAL SPECIFICATIONS -
Product Ordering
Input AC
Name Information Voltage
Power
200-220/
Wave
K 2152-2
380-400/
405
60/50 Hz
* Overall Length Including Handle, 21.6" (549mm) without handle.
Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
Phases
200
3
230
3
380
3
400
3
415
3
Voltage
Phases
200
1
220
1
380
1
400
1
415
1
1. Not rated is indicated by 4-x's in the box on the rating plate
2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
CURRENT
100%
275
60%
350

INSTALLATION

POWER WAVE 405
INPUT AC VOLTAGE & DC OUTPUT
Rated DC Output
Amps/Volts/Duty Cycle
50/60 Hz
350A / 34V / 60%
3 Phase
320A / 33V / 60%
415
1 Phase
275A / 31V /100%
1 Phase
300A / 32V / 100%
3 Phase
INPUT CURRENT
Output
300Amps@
350Amps@
32Volts(100%)
34Volts(60%)
41
37
23
22
22
275Amps@
320Amps@
31Volts(100%)
33Volts(60%)
----
64
44
40
38
LENGTH UP 61m (200 FT)
POWER WAVE 405
Output
Range
(continuous)
AMPS
5-425
Recommended
Line Cord
AWG SIZES
48
6
48
6
28
8
27
8
26
8
Line Cord
----
---
82
4
55
6
50
8
48
8
2/0
2/0
Weight
Dimensions
with Cord
HxWxD
14.7"x12.5"x
27.8"*
86.5lbs
(373x318x
(37.4 kg)
706*)mm
* Includes
handles
Size Fuse Size
80A
80A
50A
50A
50A
Size Fuse Size
-----
125A
80A
80A
80A
61-76m (200-250 FT)
2/0
2/0
A-1
Notes
Note 2
Note 2
Notes
Note 1
Note 2
Note 2