Standard Features And Accessories; Indoor Unit Accessories; Condensate Pump; Wired Remote Controller - Carrier 40MKCF Service Manual

Under ceiling/floor console ductless system sizes 18 to 54
Table of Contents

Advertisement

STANDARD FEATURES AND ACCESSORIES

Table 1—Standard Features and Accessories
Ease Of Installation
Indoor and Outdoor Compact Size
Outdoor Unit Wall Mounting Kit
Outdoor Unit Stacking Kit
Indoor Mounting Bracket
Comfort Features
Convertible Under Ceiling - - Floor Console
Microprocessor Controls
Wireless Remote Control
Automatic Air Sweep
Air Direction Control
Auto Restart Function
Cold Blow Protection On Heat Pumps
Turbo Mode
Silence Mode
Follow Me
Energy Saving Features
Sleep Mode
Stop/Start Timer
46 ° F Heating Mode (Heating Setback)
Safety And Reliability
3 Minute Time Delay For Compressor
Over Current Protection For Compressor
Crankcase Heater (standard on sizes 30 and 36 Heat Pump)
Indoor Coil Freeze Protection
Indoor Coil High Temperature Protection On Heat Pumps
Condenser High Temperature Protection On Heat Pumps
Accumulator On Heat Pumps
Ease Of Service And Maintenance
Cleanable Filters
Diagnostics
Liquid Line Pressure Taps
Suction And Discharge Pressure Taps
Application Flexibility
Low Ambient Controls (- -20F) (- -28.9C)
3- -Phase on sizes 34 & 54 (AC) and 36 & 48 (HP)
Wind Baffles
Condensate Pumps
Wired Controls
Legend
S Standard
A Accessory
Table 2—Optional Accessories
Ordering No.
Descriptions
KSACN0101AAA
Wired Remote Control
53DS- -900- -- -- -118
Condensate Pump (230v)
Low Ambient Control (for
KSALA0801AAA
cooling - - 20F)
Low Ambient Control (for
KSALA0901AAA
cooling - - 20F)
KAACH1401AAA
Crankcase Heater
KAACH1501AAA
Crankcase Heater
KAACH1201AAA
Crankcase Heater
KAACH1901AAA
Crankcase Heater
KAACH1601AAA
Crankcase Heater
Winter Start Kit (for low
KAAWS0101AAA
ambient on cooling only
systems)
Isolation Relay (Required
KHAIR0201AAA
when using Low Ambient
cooling with HP)
Hard Start Kit (Capacitor
KSAHS1501AAA
& Relay)
53DS- -900- -- -- -087
Wind Baffle
53DS- -900- -- -- -071
Wind Baffle
53DS- -900- -- -- -088
Wind Baffle
53DS- -900- -- -- -075
Stacking Kit
53DS- -900- -- -- -076
Stacking Kit
53DS- -900- -- -- -077
Wall Mount Kit
53DS- -900- -- -- -078
Wall Mount Kit
Liquid Line Solenoid for
KAALS0201LLS
Cooling Only
Liquid Line Solenoid for
KHALS0401LLS
Heat Pump
S
A
A
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
A
S
S
S
S
S
S
S
S
A
S
A
A
A
For Models
All Sizes
All Sizes
24AHA4/25HHA4 (208/230V)
24AHA4 (460V- -3)
24AHA4 Sizes 18- -36 (208/230V)
24AHA4 Size 36 (460V- -3)
24AHA4 Size 48 (208/230V)
24AHA4/25HHA4 Size 48 (460V- -3)
25HHA4 Size 48 (208/230V)
24AHA4 All Sizes
25HHA4 All Sizes
24AHA4/25HHA4 (208/230V- -1)
24AHA4 Sizes 18 & 24
24AHA4 Sizes 30- -48 / 25HHA4 Sizes
30 & 36
25HHA4 Size 48
24AHA4 Sizes 18, 24
24AHA4 Sizes 30 - - 48
24AHA4 Sizes 18, 24
24AHA4/25HHA4 Sizes 30 - - 48
24AHA4 All Sizes - - Required for Long
Line Applications
25HHA4 All Sizes - - Required for Long
Line Applications

INDOOR UNIT ACCESSORIES

Condensate Pump

Fig. 1 – Condensate Pump Accessory
On ductless fan coils, the condensate pump has a lift capability of
12 ft. (3.6 m) on the discharge side with the pump mounted in the
fan coil or 6 ft. (1.8 m) on the suction side if the pump is remote
mounted. The pump is recommended when adequate drain line
pitch cannot be provided, or when the condensate must move up to
exit.

Wired Remote Controller

For applications where the use of wireless remote control is not
desired, the MK units can be controlled by means of a wired
wall- -mounted control with an LCD display.
Fig. 2 – Wall Mounted Control with LCD Display
3
A07892

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

24aha4124ans40mkqf25hha4224ans

Table of Contents