System Components - Mircom flexnet Installation And Operation Manual

Network intelligent analog fire alarm and audio system
Hide thumbs Also See for flexnet:
Table of Contents

Advertisement

Mircom

System Components

Chassis Types
Mircom FX-2000
Fire Alarm Control Panel
Normal Condition
ENTER
December 31, 1999
TROUBLE
MONITOR
ALARM
SUPV.
QUEUE
QUEUE
QUEUE
QUEUE
SIGNAL
SILENCE
A.C. ON
PRE-ALARM
GND FAULT
GENERAL
ALARM
2nd STAGE
AUTO CANCEL
A.C. LINE
CIRCUIT
BREAKER
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
ZONE
BYPASS
BYPASS
#1
#5
#9
#13
#17
#21
#1
#5
#9
#13
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
#2
BYPASS
BYPASS
#10
BYPASS
#14
BYPASS
#18
BYPASS
BYPASS
#2
BYPASS
BYPASS
#10
BYPASS
#14
#6
#22
#6
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#23
BYPASS
BYPASS
BYPASS
BYPASS
#3
#7
#11
#15
#19
#3
#7
#11
#15
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#4
#8
#12
#16
#20
#24
#4
#8
#12
#16
Mircom FX-2000
MENU
Fire Alarm Control Panel
Normal Condition
ENTER
CANCEL
December 31, 1999
INFO
ALARM
SUPV.
TROUBLE
MONITOR
QUEUE
QUEUE
QUEUE
QUEUE
SIGNAL
FIRE
SILENCE
DRILL
A.C. ON
PRE-ALARM
GND FAULT
GENERAL
SYSTEM
ALARM
RESET
2nd STAGE
LAMP
AUTO CANCEL
TEST
A.C. LINE
CIRCUIT
BREAKER
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
#13
BYPASS
#17
BYPASS
#21
BYPASS
BYPASS
BYPASS
BYPASS
#13
#1
#5
#9
#1
#5
#9
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#2
#6
#10
#14
#18
#22
#2
#6
#10
#14
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#3
#7
#11
#15
#19
#23
#3
#7
#11
#15
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
ZONE
BYPASS
BYPASS
BYPASS
ZONE
BYPASS
BYPASS
BYPASS
ZONE
BYPASS
BYPASS
#4
#8
#12
#16
#20
#24
#4
#8
#12
#16
Mircom FX-2000
MENU
Fire Alarm Control Panel
Normal Condition
ENTER
CANCEL
December 31, 1999
INFO
ALARM
SUPV.
TROUBLE
MONITOR
QUEUE
QUEUE
QUEUE
QUEUE
SIGNAL
FIRE
SILENCE
DRILL
A.C. ON
PRE-ALARM
GND FAULT
GENERAL
SYSTEM
ALARM
RESET
2nd STAGE
LAMP
AUTO CANCEL
TEST
A.C. LINE
CIRCUIT
BREAKER
6
Model
MENU
CANCEL
INFO
FIRE
DRILL
FX-2003-12N
SYSTEM
RESET
LAMP
TEST
FX-2017-12NDS
ZONE
ZONE
BYPASS
BYPASS
#17
#21
ZONE
ZONE
BYPASS
#18
BYPASS
#22
ZONE
ZONE
BYPASS
BYPASS
#23
#19
ZONE
ZONE
BYPASS
BYPASS
#20
#24
FX-2017-12N
FX-2017-12NDS
ZONE
ZONE
BYPASS
#17
BYPASS
#21
ZONE
ZONE
BYPASS
BYPASS
#18
#22
ZONE
ZONE
BYPASS
BYPASS
#19
#23
ZONE
ZONE
BYPASS
BYPASS
#20
#24
FX-2017-12NDS
12 Amp Compact Main Chassis. This compact main chassis comes
complete with one Analog Loop Controller (99 Analog Sensors and 99
Addressable Modules), 4 Class A/B (Style Z/Y) NACs (1.7 Amp each), a
4 line by 20 character back-lit LCD display, 16 zone LED annunciator and
a 12 ampere power supply which charges 17-65 AH batteries. The FX-
2003-12N supports the FNC-2000 Network Controller Module and 2
other adder modules. This unit mounts in the BBX-1024 black backbox/
white door or BBX-1024R black backbox/red door.
This model does not support any network audio.
12 Amp Mid-Size Main Chassis. This mid-size main chassis comes
complete with one Analog Loop Controller (99 Analog Sensors and 99
Addressable Modules), 4 Class A/B (Style Z/Y) NACs (1.7 Amp each), a
DSPL-420 4 line by 20 character LCD display and a 12 ampere power
supply which charges 17-65 AH batteries. The FX-2017-12N supports
the FNC-2000 Network Controller Module and two adder modules over
the main board plus additional space in the chassis for 14 adder boards.
This chassis mounts in the BBX-1072A/DS black backbox/white door or
BBX-1072RA/ARDS black backbox/ red door.
This model does not support any network audio.
12 Amp Mid-Size Main Chassis. This mid-size main chassis comes
complete with one Analog Loop Controller (99 Analog Sensors and 99
Addressable Modules), 4 Class A/B (Style Z/Y) NACs (1.7 Amp each), a
4 line by 20 character back-lit LCD display, 16 zone LED annunciator and
a 12 ampere power supply which charges 17-65 AH batteries. The FX-
2017-12N supports the FNC-2000 Network Controller Module and two
adder modules over the main board plus additional space in the chassis
for 14 adder boards. This chassis mounts in the BBX-1072A black
backbox/white door or BBX-1072RA black backbox/ red door.
This model does not support any network audio.
12 Amp Mid-Size Main Chassis. This mid-size main chassis comes
complete with one Analog Loop Controller (99 Analog Sensors and 99
Addressable Modules), 4 Class A/B (Style Z/Y) NACs (1.7 Amp each), a
DSPL-420 4 line by 20 character LCD display, and a 12 ampere power
supply which charges 17-65 AH batteries. The FX-2017-12NDS supports
the FNC-2000 Network Controller Module and two adder modules over
the main board plus additional space in the chassis for 14 adder boards.
This chassis mounts in the BBX-1072A/DS black backbox/white door or
BBX-1072RA/ARDS black backbox/ red door.
This model does not support any network audio.
Description

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the flexnet and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF