Ipm Continuity Check; Ac Fan Motor - Pioneer YN020GMFI22M2D Service Manual

Multi split system outdoor units/two, three, four and five zones
Hide thumbs Also See for YN020GMFI22M2D:
Table of Contents

Advertisement

3. IPM continuity check

Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount
the IPM. Use a digital tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W

4. AC Fan Motor.

Measure the resistance value of each winding by using the tester.
Position
Black - Red
White - Black
Measure the resistance value of each winding by using the tester.
Normal resistance
value
(Several MΩ)
RPG20B
381Ω±8% (20℃)
342Ω±8% (20℃)
(Brand: Weiling)
(Brand: Dayang)
267Ω±8% (20℃)
253Ω±8% (20℃)
(Brand: Weiling)
(Brand: Dayang)
Digital tester
(+)Red
(-)Black
U
V
N
W
(+)Red
Resistance Value
183.6Ω±8% (20℃)
(Brand: Weiling)
206Ω±8% (20℃)
(Brand: Weiling)
Normal
resistance
value
(Several MΩ)
RPG28H
180Ω±8% (20℃)
(Brand: Wolong)
190Ω±8% (20℃)
(Brand: Wolong)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yn030gmfi22m3dYn040gmfi22m4dYn050gmfi22m5d

Table of Contents