Pioneer YN020GMFI22M2D Service Manual page 94

Multi split system outdoor units/two, three, four and five zones
Hide thumbs Also See for YN020GMFI22M2D:
Table of Contents

Advertisement

How to remove the electrical
parts.
3
Electrical
parts
1) Perform work of item 1,2.
2) Remove the four screws
fixing the IPM board.
3)
of the reactor.
4)
of the compressor.
5)
pieces of connection wires and
connectors between IPM and
PCB.
6)
Unfasten the connector
Unfasten the connector
Disconnect following 3
CN1(5p,white)
CN14(3p,white)
CN3(red or brown)
CN5(blue)
Remove the IPM board.
110 
IPM board
PCB board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yn030gmfi22m3dYn040gmfi22m4dYn050gmfi22m5d

Table of Contents