For 2015 or earlier Wall Mount Models
WB009GMFI16HLD, WB012GMFI16HLD, WB018GMFI16HLD (2015 and earlier)
De-frost
Timer
★
★
X
★
X
X
X
X
X
X
X
Auto
Operatio
Failure
Indoor unit EEPROM parameter error
Communication malfunction between indoor and
★
★
outdoor units error
Zero-crossing signal detection error
★
★
Indoor fan speed has been out of control
★
★
X
Outdoor temperature sensor(coil sensor T3 or
★
ambient temperature sensor T4) malfunction or
Outdoor unit EEPROM parameter error sensor
Indoor room temperature sensor(room sensor T1
★
or coil sensor T2) malfunction
Outdoor fan speed has been out of control
★
★
Inverter module (IPM) malfunction
★
Over-voltage or under-voltage protection
★
X
Compressor top high temperature protection
★
(OLP)
Low ambient temperature cut off in heating
★
Compressor drive malfunction
★
★
Indoor units mode conflict
★
★
Display
E0
E1
E2
E3
E5
E6
E7
P0
P1
P2
P3
P4
P5