Test Program Mode - Yamaha VS-10 Service Manual

Hide thumbs Also See for VS-10:
Table of Contents

Advertisement

TEST PROGRAM MODE (VS-10)
1. Procedure for starting Test Program
With the power turned off, press the POWER key while pressing the VOLUME key and the DSP key simultaneously. This
initiates the Test Program function.
When the Test Program is initiated, "01 DEST-Ex" appears on the FL display.
2. Procedure for selecting and executing Test Program
Using the VOLUME + (UP) key and Volume - (DOWN) key, select the Test Program and then press the INPUT key to
execute it.
3. Procedure for canceling Test Program
There are two methods for cancellation.
a. Turn off the power by pressing the POWER key of the main unit or the remote controller.
b. Select the Test Program "01 DEST-Ex" and press the INPUT key for execution. (The normal mode will be restored.)
4. Details of the Test Program function
Display
01 DEST-Ex
02 Fact.Test
03 FL+CLEAR
04 FL CHECK
1
st
time
Function
Destination display/ test program end
Destination display
J:Ja
J (Japanese)
Ex
Ex models
Factory test mode
This test mode is used for factory inspection before shipping and is not usually
used.
If the test program has been executed, it is not possible to shift to another test
program.
In such case, cancel the test program.
FL display segments all light up / BACKUP RAM CLEAR
st
1
time: FL display segments all light up and standby LED lights up.
time: RAM CLEAR is executed (RAM CLEAR OK on display*)
2
nd
* State before shipped out of the factory preset.
FL display light-up check
st
1
time: FL display segments all light up and standby LED lights up.
2
nd
time: Even number segments and digits light up and standby LED lights up.
3
rd
time: Odd number segments and digits light up.
2
nd
time
VS-10/NX-SW10
3
rd
time
10