Display
05 DSP Diag
06 Ver-A1.05
07 SUM[cdbc]
08 PrCan-OFF
09 Pr!C–P–S–
10 RemoCorrR
*
1
CAUTION:
Using this product with the protection function cancelled may cause damage to itself. Use special care for this point
when using this mode.
11
Function
The DSP DIAG (self-diagnosis) mode is initiated. (Refer to page 7 for the details.)
Microprocessor version / date display
Example of microprocessor display
Example of microprocessor date display
What is displayed varies depending on the microprocessor software.
Check sum calculation display / re-calculation
All protection cancellation function ON/OFF *
Protection operation history display / clear
C: VS-10 amplifier voltage (DC)
P: Power supply circuit voltage
S: SW-VS10 (Subwoofer) side
–: Normal
x: Abnormal
ROM collection (EEPROM) remote control data reception / data write
This test mode is not usually used.
06 Ver-A1.05
06 '00.08.23