In the Met-C1yz:
The tray pull-in mechanism is only used in the
There is no paper feed sensor
There is no pick-up solenoid
There is no paper overflow sensor in the exit tray.
A roller was removed from the duplex feed path
Maximum paper weight for duplex mode was
Slide 73
No additional notes
Differences from Met-C1ab
optional PB3150 paper tray unit (see the next
slide). It is not used in the mainframe's paper
trays.
» The main frame has a tray lock mechanism instead.
(duplex transport roller 2 was removed).
changed from 256 gsm to 169 gsm.
73