10. Check that the set screw is oriented properly by holding the control
shaft in place on the inside of the housing while attempting to rotate
the control knob on the outside of the housing.
We do not recommend removing the control gland from the
»
housing.
Always take the housing under water without a camera after
»
removing and re-installing controls.
Remove and re-install one control at a time.
»
If your housing has a shutter spring, DO NOT rotate the shutter
»
control more than 1/16th of a full rotation, otherwise, you may
accidentally bend the shutter spring or cause the spring to
"pop off" the control shaft.
Troubleshooting
Water enters the housing
•
Re-clean and re-install the back and port o-rings.
•
Take the housing underwater without a camera installed to ensure
that the leaking has been corrected.
Photos are over-exposed (too light)
•
Adjust aperture (smaller), shutter speed (faster), or ISO (lower)
setting.
•
Move light(s) farther away from your subject.
•
Adjust exposure compensation in the camera.
•
Adjust lighting power.
27