All LEDs might flash amber, blue, off, and then green during the first two seconds while the
o
connection module is powering up.
The green Health LED remains static when the frame link module powers up the SAS connection
o
module.
Fans will slowly ramp up (9 minutes maximum) until the connection module firmware boots up.
o
If the Health LED is flashing amber or off, do one of the following:
4.
Remove the module from the frame Interconnect Bay and reinstall it, pressing firmly on the
o
module and the locking latch handle to ensure it is seated properly.
Verify that the frame has enough available power to power on the connection module.
o
Verify the connection module is installed in interconnect bays 1 or 4.
o
Check the connection module status in OneView.
o
D3940 Storage Module installation guidelines
•
Installation of the D3940 Storage Module into the frame without drives requires one person.
•
Installation of the D3940 Storage Module into the frame with drives requires two people.
•
Install the D3940 Storage Module in any two adjoining frame bays.
•
Make sure the storage module fits in the available frame bays.
•
The drawer power LED will not illuminate green until a compute module containing one or more
logical JBODs that are assigned to the D3940 Storage Module is powered on.
•
In single connection module configurations: if the SAS connection module is in ICM1, then the
storage modules are only supported in device bays 1-6.
•
If the SAS connection module is in ICM4, then the D3940 Storage Modules are only supported in
device bays 7-12.
Installing D3940 Storage Module
Prepare the storage module for installation by pressing down on the storage module handle release
1.
latch, which opens the storage module handle.
NOTE: The storage module handle arrives packaged in the closed position and must be
opened prior to inserting into the frame.
Deployment 19