CAUTION: To prevent damage to electrical components, properly ground the D3940 Storage
Module before beginning any installation procedure. Improper grounding can cause ESD.
Identify the proper D3940 Storage Module.
1.
Label the drive bay locations for each drive.
2.
Remove all the drives.
3.
IMPORTANT: The replacement D3940 Storage Module must not contain drives.
Press the storage module handle release latch, and then pull out the storage module with the
4.
storage module handle.
Place the D3940 Storage Module on a flat, level work surface.
5.
Access OneView and accept the D3940 Storage Module.
6.
IMPORTANT: OneView remembers missing drive enclosures that contain one or more
logical JBODs. To clear this condition, delete all the server profiles that use the missing drive
enclosure.
From the OneView dashboard, select logical interconnects.
a.
From logical interconnects, select the SAS logical interconnect.
b.
View the alerts.
c.
Select the missing drive enclosure alert.
d.
Select the action to replace the missing drive enclosure.
e.
From the replace missing drive enclosure pop-up screen, select the replacement D3940.
f.
Click Yes, replace.
g.
Monitor the task progress to verify that it has completed.
h.
Add all the drives back into the same drive bay locations.
7.
Power up the servers.
8.
Installing the replacement D3940 Storage Module
To install the replacement storage module, see "Installing D3940 Storage Module (on page 19)."
Operations 47