Item
LED
Drive status
4
VRM
The VRM provides power to the D3940 Storage Module drive drawer by converting the 12 V input power
to the local power required by the drives and I/O adapters.
HPE Smart Array P542D RAID Controller
The following components are located in the HPE Smart Array P542D RAID Controller.
Features
•
Storage interface (SAS/SATA)
16 12Gb/s SAS physical links distributed equally across 2 x4 internal ports and 2 x4 external
o
ports
Status
Definition
Off
Removing the drive does not cause a logical drive to fail.
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
The drive is a member of one or more logical drives and predicts
amber/green
the drive will fail.
Flashing amber
The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
Product overview 10