Specifications
Environmental specifications
Specification
Temperature range
Operating
Non-operating
Short-term
Wet bulb temperature
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating
Nonoperating
Power requirement
Minimum
Maximum
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048 m (10,000 ft) or 70 Kpa/10.1 psia.
Upper nonoperating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
2
Storage maximum humidity of 90% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
12Gb SAS Connection Module specifications
Specification
Communications
Data path
Height
Depth
Width
Weight (maximum)
D3940 Storage Module specifications
Specification
Data path
Value
1
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
-5°C to 50°C (23°F to 122°F)
28ºC (82.4ºF)
38.7ºC (101.7ºF)
2
20% to 80%
5% to 95%
3 watts
40 watts
Value
•
OneView GUI
•
OneView Rest API
•
OneView interconnect serial
console
12Gb/s SAS x4 to 12 device bays
2.79 cm (1.1 in)
26.80 cm (10.55 in)
19.25 cm (7.58 in)
2.31 kg (5.10 lb)
Value
12Gb/s SAS x8 to 2 interconnect
bays
Specifications 50