Firmware; Updating The Firmware; Expanding Local Storage - HPE Synergy 12Gb SAS Storage User Manual

Hide thumbs Also See for Synergy 12Gb SAS Storage:
Table of Contents

Advertisement

REST API: /rest/alerts
For more information, see the OneView REST API Reference.

Firmware

Firmware is preinstalled on each module in the factory, but an updated, alternative, or preferred version
may be available.
The installed firmware version is displayed in OneView near the center of the Synergy 12Gb SAS
Connection Module. Access OneView and make note of the installed firmware version on each
connection module.
IMPORTANT: When two HPE Synergy 12Gb SAS Connection Modules are installed in
interconnect bays 1 and 4 of a frame, make sure that they are running the same firmware
version.

Updating the firmware

From the OneView main menu, select the Logical Enclosures option.
1.
Click Actions, and then select the Update firmware option.
2.
Select a Firmware baseline option.
3.
Select a shared infrastructure option in the Update firmware for field.
4.
Select a Logical interconnect activation option.
5.
Click OK.
6.

Expanding local storage

Local storage can be expanded by adding new logical JBOD's or logical drives, depending on how the
local storage is configured within the OneView server profile. You cannot edit an existing logical drive or
logical JBOD.
There are three ways to expand local storage:
Manually managed (on page 45)
HBA (on page 45)
RAID (on page 45)
Expanding local storage also includes adding drives to the storage module when there are empty bays.
Additional storage modules can also be added to an existing HPE Synergy 12000 Frame.