Installation And Commissioning - Lincat IH21 Installation, Operating And Servicing Instructions

Countertop induction hobs
Table of Contents

Advertisement

INSTALLATION AND COMMISSIONING

This appliance must be earthed.
If replacing the plug connect the terminals as follows:
Green and Yellow wire
Blue wire
Brown wire
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
The IH21 and IH3 appliances have a single supply cord.
The IH42 appliance has two supply cords.
Ventilation and air circulation:
Install this appliance on a level surface ensuring that all vents are unobstructed.
Any partitions, walls or furniture must be of non-combustible material.
Minimum distances to walls or adjacent equipment (see image below):
IH21 and IH3;
IH42;
IS 565 ECN 3766
Earth
E
Neutral
N
Live
L
A=100mm, B=1000mm
A=150mm, B=1000mm
Page 5 of 13