Checklist Of Enclosures; Installation And Commissioning - Lincat Opus 800 OE8013 Installation, Operating And Servicing Instructions

Electric induction hobs
Table of Contents

Advertisement

CHECK LIST OF ENCLOSURES
Warranty card
Instructions manual
Air deflector

INSTALLATION AND COMMISSIONING

This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth
Blue wire
Brown wire
Black wire
Grey wire
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
Area Error: No reference sqm
Bend Rad Error: No reference
Mat Thick Error: No reference
The fixed wiring insulation must be protected by insulated sleeving having a
Last Printed Error: No reference - Ref: Saved as Draft1
temperature rating of at least 60
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
If the supply cable is replaced, the live conductors must pass through the ferrite ring
for EMC compliance. Do not pass the neutral or earth wire through the ferrite ring.
IS 614 ECN 3862
E
Neutral N
Live
L1
Live
L2
Live
L3
o
C.