Shut down power to the entire installation at the main power distribution board and lock out
power before carrying out any installation or maintenance work.
Use only a source of AC power that complies with local building and electrical codes and
has both overload and ground-fault (earth-fault) protection.
Isolate the fixture from power immediately if any seal, cover, cable, or other component is
damaged, defective, deformed or showing signs of overheating. Do not reapply power until
repairs have been completed
Before using the fixture, check that all power distribution equipment and cables are in
perfect condition, are rated for the current requirements of all connected devices, are
protected to IP67 or higher and are of suitable type for the location (including water,
pollution, temperature and UV resistance).
Do not immerse the fixture in water or any other fluid, or install it in a location where
flooding may occur.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F).
The surface of the product can reach up to 55° C (131° F) during operation. Avoid contact
by persons and materials. Allow the fixture to cool for at least 10 minutes before handling.
Keep flammable materials well away from the fixture. Keep all combustible materials (e.g.
fabric, wood, paper) at least 10 cm (4 in.) away from the fixture.
Ensure that there is free and unobstructed airflow around the fixture.
Do not illuminate surfaces within 20 cm (8 in.) of the fixture.
Do not attempt to bypass thermostatic switches or fuses.
Do not modify the fixture in any way not described in this manual or install other than
genuine Martin™ parts. Do not stick filters, masks or other materials onto any lens or other
optical component. Use only accessories approved by Martin™ to modify the light beam.
Protection from eye injury
The Exterior Wash 200, 210 and 220 are classed Risk Group 3 according to EN 62471.
Possibly hazardous radiation emitted from this product. Do not look at operating lamp. Eye
injury may result.
To minimize the risk of eye irritation or injury, disconnect the fixture from power at all times
when the fixture is not in use, and provide well-lit conditions to reduce the pupil diameter of
anyone working on or near the fixture.
Do not look at the light output with magnifiers, telescopes, binoculars or similar optical
instruments that may concentrate the output.
Ensure that persons are not looking directly into the fixture when it lights up suddenly. This
can happen when power is applied, when the fixture receives a DMX signal, or when
certain control menu items are selected.
Wear protective glasses and other PPE (personal protective equipment) when working on
or near the fixture.
The risk group distances given below apply to the light output from one fixture only. If
fixtures can be operated in combination, light intensity can increase and you should consult
a lighting professional for safety recommendations.
Exterior Wash 200
The Exterior Wash 200 falls into the following risk groups according to EN 62471 at the
distances indicated: