Summary of Contents for Martin ExteriorWash 200 Series

  • Page 2 Martin™, Harman™ and all other trademarks in this document pertaining to services or products by Martin Professional™ or its affiliates and subsidiaries are registered as the property of Harman International Industries.
  • Page 3: Table Of Contents

    Table of contents Safety information ....................5 Introduction ......................9 Fixture overview ....................9 Before using the product for the first time ............9 Physical installation ....................10 Fixture location ....................10 Mounting the fixture ..................10 Adjusting tilt ...................... 11 Installing a diffuser ...................
  • Page 5: Safety Information

    Install, operate and service Martin™ products only as directed in their user manuals, or you may create a safety hazard or cause damage that is not covered by product warranties.
  • Page 6 Do not modify the fixture in any way not described in this manual or install other than genuine Martin™ parts. Do not stick filters, masks or other materials onto any lens or other optical component. Use only accessories approved by Martin™ to modify the light beam.
  • Page 7 0.2 m 2.7 m 12 m (8 ins.) (8.9 ft.) (39.4 ft.) DO NOT RISK GROUP RISK GROUP RISK GROUP EXPOSE At a distance of less than 2.7 m (8.9 ft.) from the fixture, the light output can potentially cause eye or skin injury before an exposed person’s natural aversion responses (blink reflex and reaction to skin discomfort) can protect them.
  • Page 8 output at less than 2 m (6.6 ft.) from the fixture and so that prolonged staring into the light output at less than 5.5 m (18 ft.) from the fixture is not expected. Protection from injury Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when installed.
  • Page 9: Introduction

    Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the fixture. Check the support pages on the Martin Professional website at www.martin.com for the most recent user documentation and technical information about the fixture. Martin™ user manual revisions are identified by the revision letter at the bottom of the inside cover.
  • Page 10: Physical Installation

    All local safety regulations and legal requirements must be observed when installing and ™ connecting the Exterior Wash 200 Series. Installation must be carried out by qualified professionals only. Contact your Martin supplier for assistance if you have any questions about how to install this product safely. Fixture location ™ Exterior Wash 200 Series fixtures are intended for outdoor use.
  • Page 11: Adjusting Tilt

    properties: stainless steel A4-70 grade according to ISO 3506 or steel grade 8.8 according to ISO 898-1). All nuts used must be self-locking. Washers must be installed between the head of each fastener and the yoke base. Referring to the illustration below, use a 12 mm (1/2 inch) shaft diameter bolt in the center hole A. Then use either two additional 12 mm bolts passing through holes B or two bolts with 8 mm (5/16 inch) shaft diameter passing through slots C to anchor the fixture.
  • Page 12: Installing A Snoot

    To install an optional diffuser lens: Shut down power to the fixture. Position the diffuser lens over the front with the labelled, smooth side facing out. With the cut-out channels in the silicone gasket facing out, align the channels in the gasket with the drain channels at the bottom of the front ring.
  • Page 13: Ac Power

    AC power Warning! Read “Safety Information” on page 5 before attempting to install an ™ Exterior Wash 200 Series fixture. Lock out power to the entire installation before working on cables and connections. Electrical installation must be carried out by qualified professionals only. For protection from dangerous electric shock, the fixture must be grounded (earthed).
  • Page 14 If you install a power plug on the power cable for temporary use, install a grounding type (earthed) plug with integral cable grip that is rated minimum 277 V, 6 A. Follow the plug manufacturer’s instructions and connect the wires in the power cable as shown in this table: Live or L Neutral or N Earth, Ground or...
  • Page 15: Control Data Link

    The data link and each connected branch must be terminated at the end by placing a 120 ohm resistor (available from Martin, P/N 04150308) across the data output hot (+) and data output cold (-) conductors of the last fixture on the chain.
  • Page 16: Setup

    Setup Warning! Read ‘Safety information’ on page 5 before operating the fixture. This section explains the fixture settings and utilities that the user has access to via the control panel. Settings are retained when the fixture is powered off. A full map of the control menu including default settings can be found on page 22.
  • Page 17: Programming A Standalone Show

    Programming a standalone show You can program a standalone routine, or show, to run without a controller or if DMX control is suddenly lost. The show can have up to 20 separate effects, or scenes, that display for up to 10 minutes each. Scenes can be programmed to fade from one scene to the next over a period of 0 to 120 seconds.
  • Page 18: Automatic Test

    Automatic test The test function allows you to verify LED performance quickly from the control panel. All LEDS are first set to 100 percent. LEDs are then tested together by color (200 & 210 models), or color temperature (220 model). Finally, each LED is tested individually. To run the automatic test from the control panel, access the control menu, select AUTOMATIC TEST and press ENTER.
  • Page 19 To set the fixture’s dimmer curve: Access the control menu and select FIXTURE CONFIG. Press ENTER. Select DIMMER CURVE and press ENTER. Select the option desired from the list above and press ENTER. Color calibration ™ The color mixing LEDs in Exterior Wash 200 and 210 fixtures are calibrated at the factory for improved uniformity.
  • Page 20: Setup Via Rdm

    To use Martin M-PC, connect a PC running this application to the data link via the Martin M-DMX USB to DMX interface box (see ‘Related Items’ on page 28). Before you can communicate with fixtures, you will need to send a Scan command from M-PC to detect the devices on the data link.
  • Page 21: Maintenance

    Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents, giving owners access to Martin’s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product’s lifetime. Please contact your Martin supplier for details.
  • Page 22: Dmx Protocol

    DMX protocol Exterior Wash 200 and Exterior Wash 210 These fixtures have two DMX control modes. See ‘Channel mode’ on page 16 for details. Four-channel mode Four-channel mode provides individual 0 to 100% control of each color. Channel Value Function 0-255 Red: 0-100% 0-255...
  • Page 23: Control Menus

    Control menus To access the control menus, press and hold the MENU button. If prompted, scroll to the user password and press ENTER. Press ▼ (down) and ▲ (up) buttons to navigate the menus. Press ENTER to select a menu option. For more information, see ‘Accessing and navigating the control menus’ on page 16. The factory default settings are shown in bold.
  • Page 24 Show Mode Behavior when no DMX control DMX State Hold Last Look signal present Black Out Fixture Config Display Lock No/Yes Password protect control menu (contd.) 0 – 999 (123) Lock Password Set user password Restore all settings to factory Factory Reset No/Yes defaults...
  • Page 25: Troubleshooting

    Correct poor connections. Repair or replace damaged cables. Electromagnetic interference Move cables away from any strong on DMX link electromagnetic fields. Have faulty fixture serviced by Martin™ Fixture defective. Service. Other device on DMX link Bypass devices on DMX link until the defective.
  • Page 26: Specifications

    Specifications Physical Length ..........................270 mm (10.7 in.) Width ..........................334 mm (13.2 in.) Height ..........................382 mm (15.1 in.) Weight ..........................13.0 kg (28.7 lbs.) Dynamic Effects All models Intensity ............................0 - 100% Exterior Wash 200 and 210 Color mixing .............................
  • Page 27 Construction Protection rating ..........................IP66 Color ................Clear anodized (standard), black or white (optional) Housing ..........................Cast aluminum Effective Projected Area (EPA) ..................... 0.1 m² (1.1 ft Impact resistance ..........................IK08 RoHS ............................Compliant Installation Orientation ............................Any Mounting ..........................Adjustable yoke Minimum distance to illuminated surfaces ................
  • Page 28 Exterior Wash 200 Series, asymmetric diffuser kit ............... P/N 91610150 Exterior Wash 200 Series, glare shield / snoot ..............P/N 91611745 Related Items Martin™ M-PC 2U incl. Martin™ M-DMX Interface Box and USB cable ....... P/N 90737070 Ordering Information Exterior Wash 200, 7°, EU, aluminum ................... P/N 90509087 Exterior Wash 200, 7°, US, aluminum ...................
  • Page 29 Photobiological Safety Warning The warning shown below is displayed on this product. If it becomes difficult or impossible to read, it must be replaced using the illustration below to reproduce a new label sized 58 x 16 mm, in black with a yellow border.
  • Page 30 Exterior Wash 200 Series User Manual...
  • Page 32 · Olof Palmes Allé 18 · 8200 Aarhus N · Denmark Tel: +45 8740 0000 · Fax +45 8740 0010...

Table of Contents