Martin ExteriorWash 200 Series User Manual page 19

Table of Contents

Advertisement

To set the fixture's dimmer curve:
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select DIMMER CURVE and press ENTER.
3.
Select the option desired from the list above and press ENTER.
Color calibration
The color mixing LEDs in Exterior Wash
uniformity. The calibration factor is not applied by default. To apply color calibration:
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select COLOR CALIBRATION and press ENTER.
3.
Select YES to apply the factory color calibration, or NO to disable it.
4.
Press ENTER.
White balance
White balance can be modified on 200 and 210 models by adjusting the amount of each color mixed in to
make white.
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select WHITE BALANCE and press ENTER.
3.
Select a color to adjust and press ENTER.
4.
Press UP or DOWN to increase or decrease the amount of that color in the white balance mix. Press
ENTER.
5.
Repeat steps 3 and 4 for the other two colors.
DMX state
There are three options for fixture behavior when there is no DMX signal or if the DMX signal is suddenly
lost. Note that for stand-alone and master/slave operation, DMX STATE must be set to SHOW MODE.
SHOW MODE: Fixture executes programmed scenes.
HOLD LAST LOOK: Fixture holds and displays the last received DMX command.
BLACKOUT (default): Fixture blacks out.
To set the desired behavior:
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select DMX STATE and press ENTER.
3.
Press UP or DOWN to select the behavior. Press ENTER.
Display lock
Unauthorized access to the control menu can be prevented by requiring a user-configurable password.
This feature is turned off by default. It can be turned on or off as follows:
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select DISPLAY LOCK and press ENTER.
3.
Select YES to enable password protection or NO to disable it. Press ENTER.
Lock password
The factory default user password is 123. The service password is 111. The user password can be reset
to any value from 0 to 999 as described below. The service password cannot be reset. To change the user
password:
1.
Press and hold the MENU button to access the control menu.
2.
If prompted for a password, press the arrow buttons to scroll to the current 3-digit password or the
service password (111). Press ENTER when the password is displayed.
3.
Select FIXTURE CONFIG from the main menu and press ENTER.
200 and 210 fixtures are calibrated at the factory for improved
TM
Exterior Wash
200 Series User Manual
19

Advertisement

Table of Contents
loading

Table of Contents