Fault message
In an error situation the LED's on the front will flash and the alarm relay will be acti-
vated. If you push the top button in this situation you can see the alarm report in the
display. If there is more than one, simply push the button to scroll through and view
them.
There are two kinds of error reports - it can either be an alarm occurring during the
daily operation, or there may be a defect in the installation.
A-alarms will not become visible until the set time delay has expired.
E-alarms, on the other hand, will become visible the moment the error occurs.
(An A alarm will not be visible as long as there is an active E alarm).
Here are the messages that may appear:
A1: High temperature alarm
A2: Low temperature alarm
A4: Door alarm
A5: Information. Parameter o16 is expired
A15: Alarm. Signal from DI1 input
A16: Alarm. Signal from DI2 input
A45: Standby position (stopped refrigeration via r12 or DI input)
A59: Case cleaning. Signal from DI1 or DI2 input
E1: Faults in the controller
E6: Fault in real-time clock. Check the battery / reset the clock.
E25: Sensor error on S3
E26: Sensor error on S4
E27: Sensor error on S5
When copying settings to or from a copying key with functions o65 or o66, the fol-
lowing information may appear:
0: Copying concluded and OK
4: Copying key not correctly mounted
5: Copying was not correct. Repeat copying
6: Copying to EKC incorrect. Repeat copying
7: Copying to copying key incorrect. Repeat copying
8: Copying not possible. Order number or SW version do not match
9: Communication error and timeout
10: Copying still going on
(The information can be found in o65 or o66 a couple of seconds after copying has
been started).
14
Manual RS8EE202 © Danfoss 08-2010
Alarms
1 = alarm
High t. alarm
Low t. alarm
Door Alarm
Max Hold Time
DI1 alarm
DI2 alarm
Standby mode
Case cleaning
Max. def time
EKC error
-
S3 error
S4 error
S5 error
Alarm destinations
The importance of the individual
alarms can be defined with a setting
(0, 1, 2 or 3)
EKC 202D
Need help?
Do you have a question about the EKC 202D and is the answer not in the manual?
Questions and answers
Is there a possibility with the EKC 202D2 to correct the temperature sensor reading offset,
Yes, the Danfoss EKC 202D can correct the temperature sensor reading offset. This is done using the parameters r09 and r10, which allow for the correction of the signal from sensors S4 and S3, respectively. Both parameters have a correction range of -10.0 K to 10.0 K.
This answer is automatically generated