Danfoss EKC 202A Instructions Manual

Danfoss EKC 202A Instructions Manual

Hide thumbs Also See for EKC 202A:

Advertisement

Available languages

Available languages

Quick Links

t
= 0 - +55°C
amb
115 V a.c.
50/60 Hz
2.0 VA
10 V < U < 256 V
DO1. Refrigeration *
DO2. Defrost *
DO3. Fan *
DO4. Alarm, light or rail
heat *
* DO1 and DO2 are 16 A relays. DO3 and DO4 are 8 A relays. Max. load must be keept.
** Gold plating ensures make function with small contact loads
*** UL-approval based on 30000 couplings
Data communication LON RS 485 / MOD-bus:
RI8KL45J 08-2010
INSTRUCTIONS
EKC 202A
EKC 202B
EKC 202C
CE (250 V a.c.)
UL *** (240 V a.c.)
10 A Resistive
10 (6) A
5FLA, 30LRA
10 A Resistive
10 (6) A
5FLA, 30LRA
6 A Resistive
6 (3) A
3FLA, 18LRA
131 VA Pilot duty
4 (1) A
4 A Resistive
Min. 100 mA**
131 VA Pilot duty
(115 V)
(115 V)
(115 V)
Type: Pt 1000 (1000 Ω /0°C ) /
Ptc 1000 (1000 Ω /25°C ) /
NTC-M2020 (5000 Ω / 25°C)
( o06)
LON
MOD-bus

Advertisement

loading

Summary of Contents for Danfoss EKC 202A

  • Page 1 INSTRUCTIONS EKC 202A (115 V) EKC 202B (115 V) EKC 202C (115 V) = 0 - +55°C Type: Pt 1000 (1000 Ω /0°C ) / Ptc 1000 (1000 Ω /25°C ) / 115 V a.c. NTC-M2020 (5000 Ω / 25°C)
  • Page 2 Gold, Or, Oro l = max. 15 m EKC 202B *) AU: Gold , Or, Oro l = max. 15 m EKC 202C *) AU: Gold, Or, Oro l = max. 15 m Instructions RI8KL45J © Danfoss 08/2010 EKC 202A, B, C...
  • Page 3 0 min 59 min 0 min Setting of minutes. 0=OFF Clock - Setting of hours 0 hours 23 hours 0 hours Clock - Setting of minute 0 min 59 min 0 min EKC 202A, B, C Instructions RI8KL45J © Danfoss 08/2010...
  • Page 4 Case cleaning Delay of output at start-up The defrost temperature cannot be dis- played. There is stop based on time Defrost in progress / First cooling after defrost Password required. Set password Instructions RI8KL45J © Danfoss 08/2010 EKC 202A, B, C...
  • Page 5: Puesta En Marcha

    Los minutos (mm) de cada una de las 6 horas. t11-t16 0 min 59 min 0 min 0=OFF Ajuste del reloj - hora 0 horas 23 horas 0 horas Ajuste del reloj - minutos 0 min 59 min 0 min EKC 202A, B, C Instructions RI8KL45J © Danfoss 08/2010...
  • Page 6 Sustituir los "ajustes de fábrica" por la programación actual Función de la sonda S5: 0 = desescarche, 1 = producto, 2 = alarma temp. condensador Función del relé 4: 1=desescarche (EKC 202A) o luz (EKC 202C), 2= alarma Desesc. /...