Test Pool Pilot (Diagnostic Menu); View Setup - Aquacal Pool Pilot Digital Nano Owner's Manual

Table of Contents

Advertisement

Page 18
For the Free Chlorine adjustment, use the following table for fine-tuning the controller output
percentage (%):
CHLORINE %
CURRENTLY
SET TO:
0% - 25%
25% - 100%
After the optimal output percentage (%) has been determined, this setting will not normally require
further adjustment. Select a Boost cycle to compensate for increased bather usage or heavy rainfalls
(which can both quickly consume chlorine).

7.4 TEST POOL PILOT (DIAGNOSTIC MENU)

1) Select MENU, press UP or DOWN arrow until "Test Pool Pilot" is displayed, and press the
SELECT button. The display will automatically toggle through the following displays. You can
also select the UP or DOWN arrow to allow cycling manually forward and back.
2) While in this feature, selecting MENU will override the remaining displays and exit back to
normal operation. The unit will automatically leave the menu and revert to normal operation after
a time frame has elapsed. The following information is displayed in the view:
"Salt = #### ppm (#.
"Add Salt ## Lbs (## Kg)" (The amount of salt needed to maintain 3000 ppm (mg/L)
"Temperature ##° F (##° C)" (The temperature of the water flowing through the Tri-Sensor)
"Cell = ## V ##.
"Amp-Hrs = ######" (The amount of current times hours of operation received by the cell)

7.5 VIEW SETUP

A program and parameter menu used to view the currently programmed settings.
1) Select MENU, press UP or DOWN arrow until "View Setup" is displayed, and press the
SELECT button. The display will automatically toggle through the following displays. You can
also select the UP or DOWN arrow to allow cycling manually forward and back.
2) While in this feature, selecting MENU will override the remaining displays and exit back to
normal operation. The unit will automatically leave the menu and revert to normal operation
after a time frame has elapsed. The following information is displayed in the view:
"Nano" or "Nano+"
"Software V #.#
"Serial #"
"Display V #.#.#.# ( The version number of Display software)
"Power Level" (Set by the factory)
"Audio Alarm On/Off"
IF FREE CHLORINE IS LOWER THAN
IDEAL RANGE...
The chlorine % output needs to be
increased.
Use the up arrow button to increase
the Chlorine Output %. Press "Select"
to lock in change.
The chlorine % output needs to be
increased.
Use the up arrow button to increase
the chlorine output %. Press "Select"
to lock in change.
g/L)" (The optimum salt level is 3000 ppm (mg/L)
#
A" (The measured voltage and current sent to the cell)
#
" (The version number of software)
#
IF FREE CHLORINE IS HIGHER THAN
IDEAL RANGE...
The chlorine % setting is too high.
Use the down arrow button to lower
output. Press "Select" to lock in change.
The free chlorine will need to be tested
frequently and the chlorine output % will
need to be adjusted as needed to attain
desired level.
The chlorine % output needs to be
decreased.
Use the down arrow button to decrease
the chlorine output %. Press "Select" to
lock in change.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pool pilot digital nano plus

Table of Contents