MESSAGE DISPLAYED
Warning!
Low Amps: Cell?
Warning!
Check/clean cell
Warning!
Low Cell Volts
Warning!
Bad temp sensor?
PROBLEM
Cell is not receiving
the expected Amps.
Cell is shorted
Cell cord is defective
Temperature is out of
range.
TYPICAL SOLUTION
Enter "Test Pool Pilot" mode through the menu. Write
down the salt level, water temperature, and cell volts
and amps.
If the volts are 24-26, then the problem is usually
caused by low salt, improperly connected,
disconnected or loose cell cord, water less than 65°F
(18.3°C), a scaled cell, or cell near end of life.
Correct as appropriate.
If the volts are less than 20, then contact Autopilot
Systems for assistance.
Installer: If the unit is configured for 230 Vac operation,
then verify the input AC voltage is not 115 Vac. Supply
correct voltages or reconfigure the unit as appropriate.
Check cell for calcium scale buildup. Clean as
needed.
Check call for wire or other debris that is shorting the
electrodes.
The cell cord has a short. Replace.
Check the Tri-Sensor cable; make sure it is not
disconnected or loose.
Check the water temperature.
If confirmed temperature is OK, contact AquaCal
AutoPilot for assistance.