Philips DVDR985 Technical Training Manual page 13

Hide thumbs Also See for DVDR985:
Table of Contents

Advertisement

9
The display shows FPDIMMER. Press PLAY to
activate the dimming feature. Press Play to con-
firm that the text on the local display was
dimmed.
10
The display shows ROUTE VID. Press Play to
advance.
11
The display shows ROUTE AUD. Press Play to
advance.
12
The display shows COLORBAR ON.Press Play
to advance. An NTSC Colorbar Pattern should
apear at the output. Press play to advance.
13
The display shows PINKNOISE ON. The monitor
should produce Pink noise.
14
The display shows PINKNOISE OFF. Press Play
to advance.
15
The display shows BE RESET. Press PLAY to
Reset the Basic Engine (Mechanism/Servo
PCB).
16
The display shows BE TRAY OPEN. Press
PLAY to open the tray. Place a RW disc in the
tray.
17
The display shows BE TRAY CLOS. Press PLAY
to close the tray.
18
The display shows BE WRITE READ. This
requires a RW disc to be in the machine. The BE
resets and a small write is preformed, and then a
read. this will take 20 seconds or so.
19
The display shows BE TRAY OPEN. This opens
the tray.
20
The display shows BE TRAY CLOS. This closes
the tray.
21
The display shows ERRORLOG READ. If there
was an error a code will be displayed. If you
press PLAY, the User/Dealer script will start an
endless loop. If the unit fails a test, the local dis-
play will display FAIL and the error code
In case of failure, the display shows " FAIL
XXXXXX "The description of the shown error
code should be found in the list to follow. Once
an error occurs, press the STOP key to jump
over the failure and to continue the diagnostics.
There is a Error Code Table in Force Manual
2064
10000 - Checksum is OK
10001 -Segment name Checksum doesn't match
or segment name segment not found
10101 - FLASH 1 Write access test failed
10201 - FLASH 2 Write access test failed
10301 - FLASH write test failed
10302 - FLASH write command failed
10303 - FLASH write test done max. number of
times
10401 - HostDec SDRAM Memory data bus test
fails.
10402 - HostDec SDRAM Memory address bus
test fails.
10403 - HostDec SDRAM Physical memory
device test fails.
10501 - HostDec SDRAM Memory data bus test
fails.
10502
HostDec SDRAM Memory address bus test
12

Advertisement

Table of Contents
loading

Table of Contents