3-5-6 New SSSWs/parameters added to this model

#1 SSSW (service soft switch setting)
SW01 (service soft switch 01: error management)
Bit
Function
0
Service error code
1
Error dump list
2
Not used
3
Not used
4 (New)
##300 series service error code
5
Not used
6
Not used
7
Not used
[Bit 4]
Even when Bit0 is set to "Not output", you can select whether or not to output ##300 series Service
Error Codes, caused by hardware malfunction.
When "Output" is selected, ##300 series Serv
When "Not Output" is selected, no Service Error Codes are displayed.
SW29 Flash ROM version up
Bit
Function
0
Not used
1 (New)
Flash ROM version up
2
Not used
3
Not used
4
Not used
5
Not used
6
Not used
7
Not used
[Bit 1]
If YES is selected, the version of Update flash ROM can be upgraded.
1
Output
Output
Output
ice Error Codes are displayed and in reports.
1
YES
1 - 40
0
Not output
Not output
Not output
0
NO