3. Vertical Termination
a.
Top and Rear Vent Clearances
See Figure 40 for clearance information.
f i r e - p a r t s . c o m
Vertical Termination Clearances
b.
Top Vent Lengths
Various venting configurations are shown in
Figures 41 and 42 from which maximum vent
runs can be determined.
Vertical Termination Vent Lengths
18
CALIBER DIRECT VENT INSTALLATION INSTRUCTIONS
Figure 40
(top vent shown)
Figure 41
Maximum Horizontal Vent Lengths
Note:
Horizontal runs will require the use of one vent
support (or metal plumber's strap) for every 5 ft of vent.
The horizontal run of vent must have a 1/4 in. rise
for every 1 ft of run towards the termination. Never
allow the vent to run downward. This could cause
high temperatures and may create a fire hazard.
30803 Rev X
Figure 42
WARNING!