5 Actual Vofs adjustment (4)
(From 4 )
Set to RST MASK 21 (blue 1023+).
Set VOL OFFSET to 255 (60 [V] ).
Are there any dark cells?
Gradually decrease the Vofs data
until dark cells disappear (Vofs should
be 024 (15 [V]) or more).
Is Vofs_max3 113 (32 [V])
or greater?
Set the lowest voltage among Vofs_max1, Vofs_
max2 and Vofs_max3 as Vofs_max.
(Determin the value for Vofs
by caluculation.)
(Round down under decimal
point.)
Is Vofs_max -Vofs_min
97 (19 [V]) or greater?
Is Vofs_max -Vofs_min
116 (23 [V]) or greater?
Value for Vofs = Vofs_max - 61 (12 [V])
Set the Vofs as value for Vofs .
(To 6 )
* Vofs=
5
6
(Check Vofs_max3 with the green 1023+ signal.)
MKS S71
VOF 255
No
Note:
Yes
This setting value becomes the value
VOF ∗∗∗
for Vofs_max3.
No
Yes
(Check the upper limit of Vofs with the blue 1023 signal.)
No
Yes
No
Yes
Vofs margin = Vofs_max - Vofs_min
[V]
* Vofs Margin =
determined
6
7
Set Vofs_max3 to 255 (60 [V]).
Replace the panel
again or abnormality
in circuits
Replace the panel
again or abnormality
in circuits
Value for Vofs = Vofs_max - 41 (8 [V])
PDP-6071PU
7
8
Vofs_max3
[STEP]
Note: Take note of the value
for Vofs_max3.
Vofs_max
[STEP]
[V]
8
A
B
C
D
E
F