Specification About The Thermal Protection - Pioneer PDP-6071PU Service Manual

Table of Contents

Advertisement

5
10.5

SPECIFICATION ABOUT THE THERMAL PROTECTION

∗ The change of HI / LO have hysterisis curve below.
Reading Value of The Sensor and FAN Drive.
T4
(Outside air 131F)
T3
(Outside air 100F)
T2
(Outside air 94F)
T1
(Outside air 82F)
T0
(Outside air 77F)
FAN: STOP
FAN: LO
Assign
Pin 76
Operation when executing FAN control command
When executing [FCNS00], [FCNS01], [FCNS02] command, detect the FAN_NG signal. When NG is detected,
it becomes shutdown. When [FCNS03] command is executed, FAN_NG detection is not operated.
Assign
Pin 149
(FAN_CONT)
Pin 17
(FAN_CONT_POW)
Set State and FAN Drive
Power
ON
OFF
[ Outline Circuit ]
U-COM
5
6
FAN: HIGH
AD Value
10bit
TEMP2
T4 setting
424
T3 setting
566
T2 setting
601
T1 setting
653
T0 setting
679
FAN: HIGH FAN: LO
H
H
H
L
PSW1
State
ON
ON
According to the reading value of above table sensor.
STB
FAN_CONT: "L"
15
H : Vo = 11V
47
L : Vo = 7.6V
17
33
149
FAN_CONT
6
7
FAN: LO
FAN: STOP
AD Value
Sensor
Aims
8bit
Temp.
(Outside Air)
106
268F
142
104F
150
97F
163
86F
170
80F
OFF
This model control the FAN drive by pin 149 (FAN ON / OFF)
and pin 17 (Change of FAN control voltage) of MAIN U-com.
L
Control
Vo
FAN_vcc
REG
Vref = 2.64V
H: On
L: Off
PDP-6071PU
7
FAN: LO
FAN: HIGH
131F
SD
Low → High
100F
High → Low
94F
STOP → Low
82F
Low → STOP
77F
Fan Operation
HIGH or LO
OFF
8
A
B
SD
C
D
E
F
193
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-6070pu