SMC Networks HRSE018-A Operation Manual page 80

Thermo chiller
Table of Contents

Advertisement

HRX-OM-R039
Chapter 9 Product Warranty
Model
Cooling method
Refrigerant
Quantity of refrigerant
Control method
Ambient temperature and humidity
Circulating fluid
Operating temperature
 1
range
 3
Cooling capacity
(50/60Hz)
Temperature stability
 5 
Pump capacity
(50/60Hz)
 6
Rated fiow
(50/60Hz)
Tank capacity
Port size
Wetted material
Power supply
Fuse
Power supply cable
*10
diameter
Applicable earth leakage
breaker capacity
Rated operating current
(50/60Hz)
Rated power consumption
(50/60Hz)
 8
Dimensions
Accessory
 9
Weight
*1 Use the product in conditions where freezing will not occur.
Consult with SMC if using in a season or region where the ambient temperature will fall below zero.
*2 If tap water is used, use water which satisfies the standard of The Japan Refregeration And Air Conditioning Industry Association
(JRA GL-02-1994/Cooling water system - circulation type - make-up water)
*3 (1)Operating ambient temp.: 25
The cooling capacity will be reduced by 100W when option T [High head pump] are selected.
*4 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.
Installation environment and power supply are within specification range and stable.
*5 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20
*6 Fluid flow to maintain the cooling capacity and the temperature stability.
The specification of the coolong capacity and the temperature stability may not be satisfied if the flow rate is lower than the rated flow.
*7 To be prepared by the customer. Use an earth leakage breaker with sensitivity of 30mA/200V in power supply specification
*8 Dimension between panels. Projection is not included.
*9 Weight when the circulating fluid is not included.
*10: The end parts of all three lead wires of the cable are untreated (bare cut).
Product Warranty
8-2
Table 8-2 Specifications List[HRSE-A-20-(T)]
HRSE012-A-20-(T)
kg
 1
 2
o
C
W
1000/1200
 4
o
C
MPa
L/min
L
Stainless steel, Copper brazing (Heat exchanger), Bronze, Brass,
A
-
A
 7
 3
4.1/5.0
A
For option T : 4.5/5.4
 3
0.58/0.74
kVA
For option T : 0.66/0.82
mm
Operation manual (Installation・Operation (Japanese)) 1pc.
kg
o
C, (2)Circulating fluid temp.: 20
HRSE018-A-20-(T)
Air-Cooled refrigerated type
R407C(HFC)
0.32
Compressor ON/OFF
Temperature: 5 to 40
Tap water, Ethylene glycol aqueous solution 15%
10 to 30
1400/1600
0.08(at 7L/min)/0.11(at 7L/min)
For option T:0.13(at 7L/min)/0.18(at 7L/min)
Approx. 5
Rc1/2
Ceramic, Carbon, PP, PE, POM, EPDM,PVC
1-phase AC200V 50/60Hz.
Allowable voltage range ±10%
3 cores x 14 AWG (2.0 mm
4.2/5.3
For option T : 4.6/5.7
0.73/0.86
For option T : 0.81/0.94
W377xD435xH615
For option T : W377xD500xH615
Fitting (for drain port) 1pc.
For option T:42
o
C, (3)Circulating fluid rated flow, (4)Criculating fluid : Tap water
o
C.
HRSE024-A-20-(T)
0.33
o
C , Humidity: 30 to 70%
1900/2200
±2
7/7
15
2
), 3m
15
4.3/5.4
For option T : 4.7/5.8
0.85/1.02
For option T : 0.93/1.10
35
0.34
HRSE Series