STANDARD Balancing Procedure Using Clip-On Weights

22 x 3. Balancing Procedures
There are many types of clip-on weights. Determine the correct application before
installing weights.
Verify that the wheel is clean and free of debris.
Remove all previous weights.
Mount tire/wheel assembly. Refer to "Mounting the Wheel on the Spindle Shaft," page 9.
Press
. Use the softkey arrows to select "STANDARD BALANCE" and press
"OK."
Select either grams or ounces by rotating the control knob and highlighting either
"g" or "oz."
Select "DYNAMIC" by rotating the control knob to highlight "
Balancing Selection," page 19.
®
Use both Dataset
arms in the UPWARD position at the clip-on weight location to
measure the distance, diameter, and rim width dimensions. Refer to "Automatic
Dataset® Arms Operation," page 30.
NOTE:
The Dataset
weight placement. Refer to "Measuring Dimensions for
Standard Clip-on Weight Balancing," page 31.
Enter the data by depressing the foot pedal. Release the Dataset
Close safety hood.
Press the green "START" button if "Hood Autostart" is disabled.
After wheel comes to a complete stop, raise the safety hood.
The GSP9200 will find the TDC for the left weight plane if "Servo-Stop" is enabled.
"Servo-Stop" will hold the wheel in the TDC position while the weight is applied. The
weight amount will be displayed in green.
®
Arms should be positioned in the location for
GSP9200 Series Wheel Balancer Operation Instructions
." Refer to "Dynamic
®
arms.