Cleaning the Condenser

The condenser is part of the refrigeration system. The condenser requires monthly cleaning.
Always disconnect power supply before carrying out Routine Maintenance.
Failure to clean the condenser will reduce the performance and life of your Polar unit and may invalidate your warranty
Upright Cabinets - G590, G591, GD879, GD880
The condenser is located below the refrigeration cabinet . These models have a removable filter which can be cleaned with a vacuum cleaner.
Upright Cabinets - G592, G593, G594, G595, U632, U633, U634, U635, CC663, CD616, CW193, CW194, CW195, CW196,
CW197, CW198.
The condenser is located above the refrigeration cabinet. These models have a removable filter which can be cleaned with a vacuum cleaner.

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.
Fault
The appliance is not working
The appliance turns on, but the
temperature is too high/low
The appliance is leaking water
The appliance is unusually loud
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat source or air flow to
the condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in the
appliance
Appliance is overloaded
The appliance is not properly levelled
The discharge outlet is blocked
Movement of water to the drain is obstructed
The water container is damaged
The drip tray is overflowing
The safety band has not been removed
Loose nut/screw
The appliance has not been installed in a level or
stable position
Action
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Clean the condenser
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Empty the drip tray (if applicable)
Remove the safety band
Check and tighten all nuts and screws
Check installation position and change if necessary