Stator Test (Red Stator)
Electric Start Engines
Manual Start Engines
1. Disconnect all stator leads.
2. Use a VOA meter and perform the following
checks.
Electric Start Engines
Test Leads To –
GRN/WHT and WHT/GRN
YEL and YEL
Manual Start Engines
Test Leads To –
GRN/WHT and WHT/GRN
BLK/WHT and BLK
YEL and YEL
NOTE: Above resistance readings are for a cold en-
gine (room temperature). Resistance will increase if
engine is warm.
If meter readings are other than specified, replace
stator.
90-814676R1 DECEMBER 1996
Ohm
Ohm
Scale
Reading
R x 100
660-710
R x 1
0.165–0.181
Ohm
Ohm
Scale
Reading
R x 100
660-710
R x 100
130-145
R x 1
0.17–0.19
Stator Test (Black Stator)
1. Disconnect all stator leads.
2. Use a VOA meter and perform the following
checks.
9 AMP Stator
Test Leads To –
Blue and Blue/White
Red and Red/White
Blue and Engine Ground
Red and Engine Ground
YEL and YEL
16 AMP Stator (398-9710A33 & 398-9710A42)
Test Leads To –
Blue and Blue/White
Red and Red/White
Blue and Engine Ground
Red and Engine Ground
YEL and YEL
NOTE: Above resistance readings are for a cold en-
gine (room temperature). Resistance will increase if
engine is warm.
If meter readings are other than specified, replace
stator.
ELECTRICAL AND IGNITION - 2A-11
Ohm
Ohm
Scale
Reading
R x 1000
5.7-8.0
R x 1
56-76
R X 1000 No Reading
R X 1000 No Reading
R x 1
.5-1.0
Ohm
Ohm
Scale
Reading
R x 1000
1000-1400
R x 1
15-30
R X 1000 No Reading
R X 1000 No Reading
R x 1
.10-.50