Ignition Troubleshooting (Engines With Black Stator)
STEP 3 – Stator Low Speed and High Speed Test
Stator Low Speed Test
DCV
ACV
DVA
1. Use Multimeter / DVA Tester 91-99750.
2. Crank engine and observe meter reading.
IGNITION VOLTAGE – 9 AMP STATOR
Tested Part
Stator Low Speed
Stator High Speed
IGNITION VOLTAGE – 16 AMP STATOR (398-9710A33 & 398-9710A42)
Selector
Tested Part
Position
Stator Low Speed
400 VDC
Stator High Speed
400 VDC
TEST RESULTS
If voltage output is low to either the stator low
speed or stator high speed, the stator or switch
box is defective. Go to stator test and test stator.
If stator tests OK, replace switch box and repeat
step.
If voltage output is good to either the stator low
speed or stator high speed, replace the switch
box and repeat step
90-814676R1 DECEMBER 1996
Selector
Red
Position
Blue Sw.
400 VDC
Box Term.
Red Sw.
400 VDC
Box Term.
Red
Blue Sw.
Box Term.
Red Sw.
Box Term.
Stator High Speed Test
DCV
ACV
DVA
Black
300 - 1000 RPM
Ground
Ground
Voltage
Black
@ 300 RPM
Ground
160 - 200
Ground
8 - 10
Reading At
Reading At
1000 - 4000 RPM
210 - 310
190 - 310
25 - 90
140 - 310
Voltage
Voltage
@ 1000 RPM
@ 4000 RPM
315 - 385
27 - 33
ELECTRICAL AND IGNITION - 2A-5
270 - 330
165 - 205

Advertisement