15.3

External connections

Connect the pluggable microphone to compatible
devices with the microphone plug (refer to figure 15.2).
1
2
figure 15.2: Microphone plug, connection
table 15.4: Microphone plug, connection
Pin
Signal
1
Indicator ring, red (cathode)
2
Indicator ring common (anode)
3
Microphone signal +
4
Microphone GND
5
Shielding
6
Indicator ring, green (cathode)
15.4

Operation

The color of the indicator ring shows the condition of
the microphone (refer to table 15.5).
table 15.5: Condition
Color
Condition
Red (on)
Microphone active
Red (flash)
Last minute of speech time
Green (on)
Request-to-speak
Green (flash)
First request
Note
When the microphone is connected to a
DCN-IDESK, it can only show that the
microphone is activated.