9.1.3
Combined devices from input to
output
Delegate microphone with transmission link to
interpreter headphones
Delegate microphone with transmission link to
delegate headphones
Delegate microphone with transmission link to
auxiliary output
table 9.3: Combined devices from input to output
Typical frequency response:
125 Hz to 20 kHz
Front-to-random sensitivity index:
> 4.6 dB
Rated equivalent sound pressure level due to inherent noise:
< 25 dB(A)
Total harmonic distortion @ overload:
< 1%
Crosstalk attenuation:
> 80 dB
9.2

Environmental conditions

table 9.4: Environmental conditions
Working conditions:
Fixed, stationary, transportable
Temperature range:
-20 to +70 °C (transport)
+5 to +45 °C (operation)
For EPS and contribution devices with an LCD, the maximum temperature is +40 °C.
Relative humidity:
< 95%
9.3

Safety

According Low-Voltage Directive (LVD) 2006/95/EC.
For European countries: according EN60065.
Marking: CE
For international countries: IEC 60065 according
CB-Scheme.
For North America:
USA: ANSI/UL 60065
Canada: CAN/CSA no. 60065
Marking c-CSA-us.
Bosch Security Systems | 2007-11 | 9922 141 70691 en
Interpreter microphone with transmission link to
interpreter headphones
Interpreter microphone with transmission link to
delegate headphones
Interpreter microphone with transmission link to
auxiliary output
en | 27

Advertisement

Table of Contents
loading

Table of Contents