Hpe 800W Flex Slot Titanium Plus Hot-Plug Power Supply; Hpe 800W Flex Slot Universal Hot-Plug Power Supply - HP apollo 4510 gen9 Setup And Installation Manual

Table of Contents

Advertisement

• Connect the equipment to a reliably grounded Secondary circuit source. A Secondary
circuit has no direct connection to a Primary circuit and derives its power from a
transformer, converter, or equivalent isolation device.
• The branch circuit overcurrent protection must be rated 27 A.
CAUTION: This equipment is designed to permit the connection of the earthed conductor of
the DC supply circuit to the earthing conductor at the equipment.
If this connection is made, all of the following must be met:
• This equipment must be connected directly to the DC supply system earthing electrode
conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC
supply system earthing electrode conductor is connected.
• This equipment must be located in the same immediate area (such as adjacent cabinets) as
any other equipment that has a connection between the earthed conductor of the same DC
supply circuit and the earthing conductor, and also the point of earthing of the DC system.
The DC system must be earthed elsewhere.
• The DC supply source is to be located within the same premises as the equipment.
• Switching or disconnecting devices must not be in the earthed circuit conductor between
the DC source and the point of connection of the earthing electrode conductor.

HPE 800W Flex Slot Titanium Plus Hot-plug Power Supply

Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power

HPE 800W Flex Slot Universal Hot-plug Power Supply

Specification
Input requirements
Rated input voltage
Rated input frequency
Value
200 to 240 V AC
240 VDC for China only
50 Hz to 60 Hz
Not applicable to 240 VDC
4.35 A at 200 VAC
3.62 A at 240 VAC
3.62 A at 240 VDC for China only
870 W at 200 VAC
870 W at 240 VAC
870 W at 240 VDC for China only
2969 at 200 VAC
2969 at 240 VAC
2969 at 240 VDC for China only
800 W at 200 VAC to 240 VAC
input
800 W at 240 VDC input for China
only
800 W at 200 VAC to 240 VAC
input
800 W at 240 VDC input for China
only
Value
200 V to 277 V AC
380 VDC
50 Hz–60 Hz
Specifications 50