Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power

HPE 800W Flex Slot -48VDC Hot-plug Power Supply

Specification
Input requirements
Rated input voltage
Rated input current
Rated input power (W)
Rated input power (BTUs per
hour)
Power supply output
Rated steady-state power (W) 800 W at -40 VDC to -72 VDC
Maximum peak power (W)
WARNING: To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel, as defined by the NEC and
IEC 60950-1, Second Edition, the standard for Safety of Information Technology
Equipment.
100 to 127 VAC
200 to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
Not applicable to 240VDC
9.4 A at 100 VAC
4.5 A at 200 VAC
3.8 A at 240 VDC for China only
940 W at 100 VAC
900 W at 200 VAC
912 W at 240 VDC for China only
3207 at 100 VAC
3071 at 200 VAC
3112 at 240 for China only
800 W at 100 VAC to 127 VAC
input
800 W at 200 VAC to 240 VAC
input
800 W at 240 VDC input for China
only
800 W at 100 VAC to 127 VAC
input
800 W at 200 VAC to 240 VAC
input
800 W at 240 VDC input for China
only
Value
-40 VDC to -72 VDC
-48 VDC nominal input
26 A at -40 VDC input
19 A at -48 VDC input, nominal
input
12.4 A at -72 VDC input
936 W at -40 VDC input
912 W at -48 VDC input, nominal
input
900 W at -72 VDC input
3194 at -40 VDC input
3112 at -48 VDC input, nominal
input
3071 at -72 VDC input
800 W at -40 VDC to -72 VDC
Specifications 49