Connect Signal Cable - Pioneer Inverter+ WAS Series Installation Manual

Ductless mini split system air conditioner / heat pump 9,000 btu/h. through 36,000 btu/h.
Hide thumbs Also See for Inverter+ WAS Series:
Table of Contents

Advertisement

Step 6: Connect signal cable
The signal cable enables communication between
the indoor and outdoor units. You must first
choose the right cable size before preparing it for
connection.
Cable Types
Outdoor Power Cable:
Signal Cable: H07RN-F
Minimum Cross-Sectional Area of
Power and Signal Cables
North America
Appliance Amps (A)
10
13
15
20
30
Other Regions
Rated Current of
Appliance (A)
> 3 and  6
> 6 and  10
> 10 and  16
> 16 and  25
> 25 and  32
> 32 and  40
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal
cable, fuse, and switch needed is determined
by the maximum current of the unit. The
maximum current is indicated on the nameplate
located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse,
or switch.
H07RN-F
AWG
18
16
14
12
10
Nominal Cross-Sectional
Area (mm²)
0.75
1
1.5
2.5
4
6
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner' s circuit board (PCB) is
designed with a fuse to provide overcurrent
protection. The specifications of the fuse
are printed on the circuit board, such as:
T3.15A/250VAC, T5A/250VAC, etc.
Prepare the cable for connection:
1.
Using wire strippers, strip the rubber jacket
a.
from both ends of signal cable to reveal
about 40mm (1.5 in) of the wires inside.
Strip the insulation from the ends of the
b.
wires.
Using wire crimper, crimp u-type lugs on
c.
the ends of the wires, if needed.
PAY ATTENTION TO MAKE GOOD CONTACT
While crimping wires, make sure to make good
electrical contact between the wire and terminal
pen front panel of the indoor unit.
2. O
Using a screwdriver, open the wire box cover
3.
on the right side of the unit. This will reveal
the terminal block.
The Wiring Diagram is located
on the inside of the indoor unit's
front panel or under this cover.
WARNING
ALL WIRING MUST PERFORMED STRICTLY
IN ACCORDANCE WITH THE WIRING
DIAGRAM LOCATED ON THE INSIDE OF THE
INDOOR UNIT'S FRONT PANEL or UNDER COVER.
Unscrew the cable clamp below the terminal
4.
block and place it to the side.
Facing the back of the unit, remove the plastic
5.
panel on the bottom left-hand side.
Terminal block
Wire cover
Screw
Cable clamp
Fig. 3.9
Page 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inverter++ was seriesInverter++ wys series

Table of Contents