Defect ID: DEFECT000493407
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.3.0
Symptom: By default FOS SNMP will allow SNMP v1/v3 SET operation.
Condition: FOS SNMP write access is enabled by default.
Workaround: User have to use snmpconfig –set seclevel command to change the security level to "no access" in
order to block SNMP SET option.
Defect ID: DEFECT000494270
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.1.0
Symptom: Customer might see devices reported as unauthorized when they try to login to a switch even when
DCC policy is configured properly. Sometimes when the DCC policy is activated, some of the ports
might bounce.
Condition: The WWN that starts with "80" has the most possibility to hit this issue. The issue might also be seen
when the device WWNs starts with "C0", "50", "20", or "10".
Workaround: Avoiding the device WWN that starts with "80" or greater from DCC policy would resolve the
issue.
Defect ID: DEFECT000497464
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.3.0
Symptom: 8G port blade displays auto max speed 16G when previous port blade was 16G and had auto max
speed configured.
Condition: A 16G port blade configured with auto max speed or 16G is blade swapped with an 8G blade.
Workaround: Modify the port configuration to auto speed negotiate on the 16G port blade before blade swap
with an 8 G port blade/
Recovery: Modify the port configuration to a supported speed using portcfgspeed CLI or reset the port to default
auto speed negotiation (ASN) using portcfgdefault CLI.
Defect ID: DEFECT000497810
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.1.1
Symptom: Core blade faults when dport tests are being run on ICL ports and ports are disabled.
Condition: Disable port under testing
Workaround: Don't disable ports when dport tests are in progress.
Defect ID: DEFECT000498723
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.3.0
Symptom: Portperfshow does not display traffic for E-Port while portdportesting is running.
Condition: When portdporttest is running on ports.
Workaround: Don't run portperfshow when a portdporttest is running.
Fabric OS 7.4.1a Release Notes v3.0
Defects Closed with Code Change in FOS 7.4.0
Probability: Medium
Technology: Management
Technology Area: SNMPv2, SNMPv3 & MIBs
Probability: Low
Technology: Security
Technology Area: Fabric Authentication
Probability: Low
Technology: Other
Technology Area: Other
Probability: Low
Technology: Monitoring/RAS
Technology Area: Diagnostic Port (D_Port)
Probability: Low
Technology: Monitoring/RAS
Technology Area: Port Log
Page 99 of 142