Defect ID: DEFECT000547921
Technical Severity: High
Product: FOS
Reported In Release: FOS7.3.1
Symptom: In an AG fabric or NPIV environment, device is not found or HBA detects SCSI command timeout
and fabric switch stops routing AG switch/NPIV device traffic.
Condition: This may occur when fabric switch is configured for session based zoning and a device connected to
AG switch or an NPIV device, that is not in any zone database, is enabled. This causes all traffic
going through the same fabric switch F-port to be disrupted. This issue only impacts 16G fabric
switch running FOSv7.4.0, FOSv7.3.1 and FOSv7.2.1d
Workaround: Use hard zoning on fabric switch, or add the device into zoning database first before bringing it
online.
Recovery: Upon hitting this issue, the user may bring up ANY zoned member on AG switch or NPIV, that is
using the fabric switch F-Port, to recover.
.
Defect ID: DEFECT000548153
Technical Severity: High
Product: FOS
Reported In Release: FOS7.4.0
Symptom: Flow Generator traffic through the VE port may affect real I/O traffic on the same or other VE ports.
Condition: Flow Generator traffic through the VE port with real I/O traffic on the same or other VE ports.
Workaround: Flow Generator traffic over VE port is supported only if no other traffic is running on any of the
VE ports on that blade or switch platform.
Defect ID: DEFECT000548700
Technical Severity: High
Product: FOS
Reported In Release: FOS7.4.0
Symptom: A learning flow created on an egress port shows frame size as "--" after multiple monitoring resets or
the total frame size is sometimes off by 8 bytes.
Condition: User has a learned monitoring flow created on the egress port.
Recovery: Deactivate and reactivate the flow.
Defect ID: DEFECT000548721
Technical Severity: High
Product: FOS
Reported In Release: FOS6.4.3
Symptom: A E-port is fenced even after port fencing has been disabled.
Condition: This issue would only happen if E-port and port classes are configured with the same thresholds for
ST area. Disable port fence did not take care of the earlier fenced E-port properly under this
condition.
Workaround: Use the E-Port only threshold to monitor the State change of ISLs alone OR
to monitor all the ports in general, choose a different threshold value for E-port threshold and port
class threshold (probably E-Port threshold + 5 ).
Recovery: Bouncing the port
Fabric OS 7.4.1a Release Notes v3.0
Defects Open in FOS 7.4.0
Probability: Low
Technology: Virtualization
Technology Area: Access Gateway
Probability: High
Technology: Monitoring/RAS
Technology Area: Flow Vision: Flow Generator
Probability: Low
Technology: Monitoring/RAS
Technology Area: Flow Vision: Flow Monitor
Probability: Low
Technology: Monitoring/RAS
Technology Area: Fabric Watch
Page 89 of 142

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetVanta 7100 IP PBX and is the answer not in the manual?

This manual is also suitable for:

Netvanta 7100

Table of Contents