Brocade Fabric OS v7.4.1a
Release Notes v3.0
February 24, 2016

Document History

Document Title
Brocade Fabric OS v7.4.1a Release Notes v1.0
Brocade Fabric OS v7.4.1a Release Notes v2.0
Brocade Fabric OS v7.4.1a Release Notes v3.0
Fabric OS 7.4.1a Release Notes v3.0
Summary of Changes
Initial Release
Remove SmartOptics 16G DWDM
optics and add Finisar optics P/Ns
under the new support section
Updated DEFECT 000578406 info
in the Closed with Code Change in
Fabric OS v7.4.1.a. Add 6543 to
supported under Brocade Analytic
Monitoring Platform section of
Important Notes
Publication Date
December 18, 2015
January 13, 2016
February 24, 2016
Page 1 of 142

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN NetVanta 7100 IP PBX

  • Page 1: Document History

    Brocade Fabric OS v7.4.1a Release Notes v3.0 February 24, 2016 Document History Document Title Summary of Changes Publication Date Brocade Fabric OS v7.4.1a Release Notes v1.0 Initial Release December 18, 2015 Brocade Fabric OS v7.4.1a Release Notes v2.0 Remove SmartOptics 16G DWDM January 13, 2016 optics and add Finisar optics P/Ns under the new support section...
  • Page 2 © 2016 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
  • Page 3: Table Of Contents

    Contents Document History ............................1 Overview ..............................8 Enhancements and Resolution of Important Defects ................... 8 FOS v7.4.1 Additional Hardware Platform Support ....................8 FOS v7.4.1 New Features & Support........................8 FOS v7.4 Obsoleted FOS Features ......................9 FOS v7.4 New Feature Descriptions ....................... 10 New Hardware Support ............................
  • Page 4 Dynamic D_Port and On-demand D_Port with DWDM..................13 CLI Command Hierarchical Help Display ......................13 Peer Zoning Support .............................. 13 Target Driven Zoning support..........................13 Lossless DLS enhancement ..........................13 FCR enhancements ............................... 14 Location Embedded LSAN zone ........................14 Increase Number of Imported Proxy Devices ....................
  • Page 5 Sort zoneShow Command Output by WWN ...................... 16 Indicate offline members in zoneShow output ....................16 Traffic Isolation (TI) Zoning Enforcement enhancement ................. 16 TI Failover Disabled Zone Message ........................17 FICON Enhancements ............................17 MAPS notification to FMS CUP .......................... 17 ConfigUpload and ConfigDownload of FMS Mode ...................
  • Page 6 SNMP Support ............................... 28 Obtaining the MIBs ............................29 Blade Support ............................29 DCX/DCX-4S Blade Support ..........................29 DCX/DCX-4S Blade Support Matrix........................29 DCX 8510-8/DCX 8510-4 Blade Support ......................29 DCX 8510-8/DCX 8510-4 Blade Support Matrix ..................... 29 Power Supply Requirements for Blades in DCX/DCX-4S ................. 30 Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 ..........
  • Page 7 Closed with Code Change in Fabric OS v7.4.1 ..................... 51 Open Defects in Fabric OS v7.4.0 ........................80 Closed with Code Change in Fabric OS v7.4.0 ..................... 95 Closed without Code Change in Fabric OS v7.4.0 ..................... 134 Fabric OS 7.4.1a Release Notes v3.0 Page 7 of 142...
  • Page 8: Overview

    Overview FOS v7.4.1a is a patch release based on FOS v7.4.1. All hardware platforms and features supported in FOS v7.4.1 are also supported in FOS v7.4.1a. This release contains fixes for defects. Enhancements and Resolution of Important Defects DEFECT000576282 - Brocade switches hareboot due to Out of Memory (OOM) condition. •...
  • Page 9: Fos V7.4 Obsoleted Fos Features

    vTap supports automatic discovery of Analytic F_Port (AF_Port) when a Brocade Analytics Monitoring Platform is attached to the fabric. An AF_Port is a mirror port on the Analytics Monitoring Platform designated as the destination of information sent from vTap-enabled ports on a fabric switch.
  • Page 10: Fos V7.4 New Feature Descriptions

    FOS v7.4 New Feature Descriptions New Hardware Support FOS v7.4 adds support for the following new hardware: Brocade-branded 4GB external USB flash drive • IP Extension features for Brocade 7840 FOS v7.4 introduces IP Extension support for the Brocade 7840. Users can use this capability to extend IP storage for replication and disaster recovery in much the same way as Fibre Channel storage while taking advantage of the compression, encryption, QoS, and trunking features available in the Brocade 7840.
  • Page 11: Traffic Control List

    Untagged and single tagged packets are supported. • Stacked/double (IEEE 802.1ad) tagged packets from hosts are not supported. Packets will be dropped. • Traffic Control List FOS v7.4 supports Traffic Control List (TCL) to manage and route IP flows. Each TCL is identified by a unique user configured name.
  • Page 12: Monitor Fcip Circuit Qos

    Monitor FCIP circuit QoS FOS v7.4 enhances FCIP QoS monitoring in MAPS to add monitoring of Fibre Channel QoS parameters at circuit level. The circuit QoS monitoring combined with the tunnel QoS monitoring available since FOS v7.3 provides additional granularity to monitor the FCIP link performance. Monitor FCIP circuit RTT and jitter on 7800 and FX8-24 MAPS monitors circuit round trip time (RTT) and jitter statistics in FOS v7.3 on Brocade 7840.
  • Page 13: Scalability Improvement

    Scalability Improvement FOS v7.4 increases the scalability limit supported by Flow Vision. In particular, the total number of sub-flows supported by chassis switches is increased to 2048 and by fixed port switches is increased to 512. Identify All Devices in a Flow FOS v7.4 supports displaying all zoned devices in a flow by introducing a new option -allzoned to the Flow Vision command.
  • Page 14: Fcr Enhancements

    FCR enhancements FOS v7.4 has a number of enhancements in FCR. These enhancements include: Location Embedded LSAN zone FOS v7.4 introduces the location-embedded LSAN zone feature. A location-embedded LSAN zone specifies in the LSAN zone name the remote fabric ID that shares devices. The corresponding FCR switch will use this information in the LSAN zone names to store only these entries for the locally connected edge fabric.
  • Page 15: Time Server Enhancements

    Time Server Enhancements FOS v7.4 enhances Time Server to support Network Time Protocol (NTP) server configuration distribution to Access Gateway switches. This enhancement allows AGs, including cascaded AG connections, to receive the same NTP server configuration from a connected fabric. SNMP Enhancements FOS v7.4 implements the following SNMP enhancements.
  • Page 16: Sort Zoneshow Command Output By Wwn

    Firmware Integrity Check FOS v7.4 introduces a firmwareCheck CLI command to check the integrity of firmware packages already installed on the switch. If any of the files or packages as part of firmware has been changed, the firmware integrity check will fail and notify users which package has failed the check. Challenge-Response Authentication FOS v7.4 introduces support for SSH servers configured with “keyboard-interactive”...
  • Page 17: Ti Failover Disabled Zone Message

    TI Failover Disabled Zone Message FOS v7.4 adds a RASLOG message ZONE-1060 to warn users if the TI zone dedicated path is the only path available between two domain IDs. FICON Enhancements FOS v7.4 adds the following FICON related enhancements : MAPS notification to FMS CUP FOS v7.4 supports a new MAPS FICON notification action.
  • Page 18: Portstatsshow Command Display Txq Latency

    portStatsShow Command Display TXQ Latency FOS v7.4 enhances the portStatsShow CLI command to display the ASIC transmit queue (TXQ) latency information for each virtual channel (VC). Support De-bouncing of Loss of Signal for Fixed Speed and Auto Negotiate Ports FOS v7.4 expands loss of signal de-bouncing for both fixed-speed and auto-negotiated ports in any port state. FOS v7.4 adds a “mode 2”...
  • Page 19: Optionally Licensed Software

    Optionally Licensed Software Fabric OS v7.4 includes all basic switch and fabric support software, as well as optionally licensed software that is enabled via license keys. Optionally licensed features include: Brocade Ports on Demand Brocade Ports on Demand Brocade Ports on Demand Brocade Ports on Demand —...
  • Page 20 these LUNs. DataFort Mode tape encryption and compression is supported beginning with the FOS v6.2.0 release on DCX platforms. Availability of the DataFort Compatibility license is limited; contact your vendor for details. Advanced Extensio Advanced Extensio Advanced Extensio Advanced Extension n n n — This license enables two advanced extension features: FCIP Trunking and Adaptive Rate Limiting.
  • Page 21 Note: Note: The EICL license supports a maximum of nine DCX 8510 chassis connected in a full mesh topology or up Note: Note: to twelve DCX 8510 chassis connected in a core-edge topology. Refer to the Brocade SAN Scalability Guidelines document for additional information. WAN Rate Upgrade 1 License WAN Rate Upgrade 1 License WAN Rate Upgrade 1 License...
  • Page 22: Temporary License Support

    Temporary License Support The following licenses are available in FOS v7.4 as Universal Temporary or regular temporary licenses: Fabric (E_Port) license • Extended Fabric license • Trunking license • High Performance Extension license • Advanced Performance Monitoring license (feature not supported) •...
  • Page 23: Supported Switches

    Supported Switches FOS v7.4 supports the following platforms: 300, 5100, 5300, 7800, VA-40FC, Brocade Encryption Switch, DCX, DCX-4S • 6510, 6505, 6520, 7840, DCX 8510-8, DCX 8510-4 • FC8-16, FC8-32, FC8-48, FC8-64, FX8-24, FS8-18, FCOE10-24 • FC16-32, FC16-48, FC16-64, FC8-32E, FC8-48E •...
  • Page 24: Technical Support

    Technical Support Contact your switch supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information immediately available: 1. General Information Technical Support contract number, if applicable Switch model Switch operating system version Error numbers and messages received supportSave supportSave command output and associated files...
  • Page 25: Fos Migration Considerations

    FOS Migration Considerations This section contains important details to consider before migrating to or from this FOS release. FOS Upgrade and Downgrade Special Considerations Peer zoning and target driven zoning should be used in a fabric with all switches running FOS v7.4 or later. If peer zones have been created in a mixed fabric with switches running FOS v7.3 and FOS 7.4, peer zones created with FOS 7.4 switch are distributed to FOS 7.3 switches.
  • Page 26: Important Notes

    Important Notes This section contains information that you should consider before you use this Fabric OS release. Brocade Network Advisor Compatibility Brocade Network Advisor greatly simplifies the steps involved in daily operations while improving the performance and reliability of the overall SAN and IP networking environment. Brocade Network Advisor unifies, under a single platform, network management for SAN, LAN and converged networks.
  • Page 27: Fabric Os Compatibility

    Fabric OS Compatibility The following table lists the earliest versions of Brocade software supported in this release, that is, the • earliest supported software versions that interoperate. Brocade recommends using the latest software versions to get the greatest benefit from the SAN. To ensure that a configuration is fully supported, always check the appropriate SAN, storage or blade •...
  • Page 28: Nos (Vdx Platform) Interoperability

    NOS (VDX Platform) Interoperability Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later Brocade VDX8770 NOS 3.0 or later Brocade VDX6740 NOS 5.0 or later Notes: Notes: Notes: Notes: When directly attached to a Host or Target that is part of an encryption flow. These platforms may not be directly attached to hosts or targets for encryption flows.
  • Page 29: Obtaining The Mibs

    Obtaining the MIBs You can download the MIB files required for this release from the downloads area of the MyBrocade site. To download the Brocade-specific MIBs from the Brocade Technical Support website, you must have a user name and password. Use the following steps to obtain the MIBs you want. 1.
  • Page 30: Power Supply Requirements For Blades In Dcx/Dcx-4S

    DCX 8510-8/DCX 8510-4 Blade Support Matrix FC8-64 64 port 8Gbit port blade With any mix and up to 8/4 of each. No restrictions around intermix. Note: Note: FC8-16, FC8-32, FC8-48 blades are not supported on DCX 8510 Note: Note: platforms. FC8-32E, FC8-48E1 FOS v7.0.1 or later.
  • Page 31: Typical Power Supply Requirements Guidelines For Blades In Dcx 8510-8

    Power Supply Requirements for Blades in DCX/DCX-4S DCX/DCX-4S DCX/DCX-4S Type of @110 VAC @200-240 VAC Blades Comments Blade (Redundant (Redundant configurations) configurations) FS8-18, Intelligent Not Supported DCX: 2 or 4 Power For DCX with three or more FS8-18 • FX8-24, Blade Supplies Blades, (2+2) 220 VAC Power Supplies...
  • Page 32 Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) DCX 8510-8 DCX 8510-8 Configured Type of @110 VAC @200-240 VAC Number of...
  • Page 33 Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) DCX 8510-8 DCX 8510-8 Configured Type of @110 VAC @200-240 VAC Number of...
  • Page 34: Typical Power Supply Requirements Guidelines For Blades In Dcx 8510-4

    Typical Power Supply Requirements Guidelines for Blades in DCX 8510-4 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specificationsin the 8510-4 Backbone Hardware Reference Manual) DCX 8510-4 DCX 8510-4 ConfiguredNumber Type of @110 VAC @200-240 VAC Blades...
  • Page 35: Access Gateway

    If FOS v7.2 or later is factory installed (or by firmwarecleaninstall), Adaptive Networking features are • always available. This matches the behavior of the Brocade 6520 and all products shipping with prior versions of FOS and with the Adaptive Networking license factory installed. Ports will come up in AE mode by default If the remote port supports QOS and is not explicitly disabled, the link will come up in QOS mode.
  • Page 36: Encryption Behavior For The Brocade Encryption Switch (Bes) And Fs8-18

    Logical Switches and the Default Switch. Any Gen 5 ports (Condor3 based) assigned to that Logical Switch will be configured with that Logical Switch’s EHT setting. Any 8G ports (Condor2 based) will continue to share the EHT value configured for the Default Switch. For more information on EHT behaviors and recommendations, refer to the Brocade SAN Fabric Resiliency Best Practices v2.0 document available on www.brocade.com.
  • Page 37: Fcip (Brocade 7800 And Fx8-24)

    FCIP (Brocade 7800 and FX8-24) Any firmware activation will disrupt I/O traffic on FCIP links. • Latency measurements supported on FCIP Tunnels:1GbE & 10GbE - 200ms round trip time and 1% loss. • After inserting a 4G SFP in GE ports of an FX8-24 blade or 7800 switch, sometimes “sfpshow” output •...
  • Page 38: Fcoe/Dcb/Cee (Fcoe10-24)

    FCoE/DCB/CEE (FCOE10-24) When upgrading a DCX/DCX-4S with one or more FCOE10-24 blades from FOS v6.x to FOS v7.0.0 or later, • the user should carefully review Chapter 5 of the FOS v7.0.0 Converged Enhanced Ethernet Administrator’s Guide. Ethernet L2 traffic with xSTP Hello timer set to less than or equal to 3 seconds may experience momentary •...
  • Page 39: Fcr And Integrated Routing

    Ethernet switch services must be explicitly enabled using the command “fosconfig –enable ethsw” before • powering on an FCOE10-24 blade. Failure to do so will cause the blade to be faulted (fault 9). Users can enable ethsw after upgrading firmware without FC traffic interruption. Upgrading firmware on a DCX or DCX-4S with one or more FCOE10-24 blades from FOS v6.4.1_fcoe1 to •...
  • Page 40: Ficon

    To connect between a switch and an HBA at 16 Gbps, both sides must be in the same mode (fixed speed, • and FEC on or off) for them to communicate at that rate. If only one port has FEC enabled, neither port will be able to see the other.
  • Page 41: Port Mirroring

    Example Output: 36ed40 In_Sync Disabled (Port Throttled) Port Mirroring Port Mirroring is not supported on the Brocade 7800. • Virtual Fabrics When creating Logical Fabrics that include switches that are not Virtual Fabrics capable, it is possible to • have two Logical Switches with different FIDs in the same fabric connected via a VF incapable switch. Extra caution should be used to verify the FIDs match for all switches in the same Logical Fabric.
  • Page 42: Brocade Analytics Monitoring Platform

    Brocade Analytics Monitoring Platform vTap is only supported on Brocade Gen5 SAN products including: 6510, 6505, 6520, , DCX 8510-8, DCX • 8510-4, 6543, 6545, 6546, 6547, 6548, M6505 vTap flows do not need to be deactivated when monitored switches are upgraded from FOS v7.4.0b to FOS •...
  • Page 43 Class 3 frames that have been trapped to CPU will be discarded in the following scenarios on DCX/DCX- • 4S/DCX 8510 during the following conditions: HA failover on DCX/DCX-4S/DCX 8510 platforms while running FOS v7.0 or later firmware • Firmware upgrade from v7.0 to a later release on Brocade 300, 5100, VA-40FC, 5300, 6510 •...
  • Page 44: Defects

    Defects Closed with Code Change in Fabric OS v7.4.1a This section lists the defects with Critical, High and Medium Technical Severity closed with a code change. Defect ID: DEFECT000495229 Technical Severity: High Probability: Medium Product: Brocade Fabric OS Technology Group: Management Reported In Release: FOS7.2.1_HIL Technology: Software Installation &...
  • Page 45 Defects Closed with Code Change in FOS 7.4.1a Defect ID: DEFECT000539342 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology Group: Monitoring Reported In Release: FOS7.4.0 Technology: MAPS - Monitoring and Alerting Policy Suite Symptom: System may encounter mdd process killed by Software Watchdog and show console message "Detected termination of process mdd0"...
  • Page 46 Defects Closed with Code Change in FOS 7.4.1a Defect ID: DEFECT000563638 Technical Severity: High Probability: Medium Product: Brocade Fabric OS Technology Group: Distance Reported In Release: FOS7.4.0 Technology: FCIP - Fibre Channel over IP Symptom: Observed FICON CHPID IFCCs and job failures. Condition: When FICON Tape Pipelining needs to handle an abnormal sequence such as Attention in REPOSITION_PENDING_STATE.
  • Page 47 Defects Closed with Code Change in FOS 7.4.1a Defect ID: DEFECT000567540 Technical Severity: High Probability: High Product: Brocade Fabric OS Technology Group: Management Reported In Release: FOS8.0.1 Technology: Configuration Fundamentals Symptom: System may encounter Raslogs ERCP-1000, RAS-1000 during firmwaredownload. For example: “[ERCP-1000], 7, FFDC | CHASSIS, CRITICAL, Skybolt214, Multiple DDR ECC errors are detected and the system will reload automatically”.
  • Page 48 Defects Closed with Code Change in FOS 7.4.1a Defect ID: DEFECT000570370 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology Group: Management Reported In Release: FOS8.0.0 Technology: Configuration Fundamentals Symptom: First Failure Detection Capture (FFDC) might be seen after D-port test. Condition: FFDC seen after a D-port test is ran on BR7840 which may cause memory corruption.
  • Page 49 Defects Closed with Code Change in FOS 7.4.1a Defect ID: DEFECT000576960 Technical Severity: Medium Probability: High Product: Brocade Fabric OS Technology Group: Management Reported In Release: FOS7.4.0 Technology: Configuration Fundamentals Symptom: The Restore Factory Defaults command may fail midway and certain features like zoning config may not be set to default values.
  • Page 50 Defects Closed with Code Change in FOS 7.4.1a Defect ID: DEFECT000580719 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology Group: Traffic Management Reported In Release: FOS7.4.0_AMP Technology: Fibre Channel Routing Symptom: Adding AMP to fabric caused device to loss connectivity. Condition: After upgrade from FOS v7.3.x to v7.4.0b, with existing F/E port on an ASIC chip, enable AE port on the same chip may cause routing problems in the switch.
  • Page 51 Closed with Code Change in Fabric OS v7.4.1 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change. Defect ID: DEFECT000470033 Technical Severity: Medium Probability: Medium Product: Brocade Fabric OS Technology: Other Reported In Release: FOS7.1.1 Technology Area: Other Symptom: In switchshow output the status field is not properly aligned for the LISL ports display entries (where it is shifted slightly to the right).
  • Page 52 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000515289 Technical Severity: Medium Probability: Low Product: Brocade Fabric OS Technology: Monitoring Reported In Release: FOS7.1.2 Technology Area: MAPS - Monitoring and Alerting Policy Suite Symptom: IPfilter policies not enforced on standby CP, until after hafailover, and may be enforced on IPFC address on VF.
  • Page 53 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000539584 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Monitoring Reported In Release: FOS7.4.0 Technology Area: Hardware Monitoring Symptom: 2KM QSFP ICL ports may see link errors such as CRC and FEC errors. The link errors may result in credit or frame loss and trigger link reset.
  • Page 54 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000546101 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Security Reported In Release: FOS7.4.0 Technology Area: Encryption Symptom: FFDC is generated in Blade processor. Condition: This is seen in encryption environment (BES/FS8-18), when BLS/ELS frame gets corrupted and is redirected to Blade Processor.
  • Page 55 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000547759 Technical Severity: Medium Probability: Low Product: Brocade Fabric OS Technology: Security Reported In Release: FOS7.1.0 Technology Area: Security Vulnerability Symptom: Customer was unable login with RADIUS user to switch after changed password expiration period by "passwdcfg --set -maxpasswordage 90"...
  • Page 56 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000548713 Technical Severity: High Probability: Medium Product: Brocade Fabric OS Technology: Distance Reported In Release: FOS7.2.0 Technology Area: FCIP - Fibre Channel over IP Symptom: Disk to disk mirroring application failures with associated XTUN-1001 RASLOG messages. Condition: When a specific Disk to Disk mirroring application encounters IO errors over a 7800 or FX8-24 FCIP Tunnel, it will issue an odd sequence of Extended Link Services commands (concurrent LOGO/LOGO and PLOGI sequences).
  • Page 57 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000549278 Technical Severity: Medium Probability: High Product: Brocade Fabric OS Technology: Distance Reported In Release: FOS7.4.0 Technology Area: FCIP - Fibre Channel over IP Symptom: The 'portshow lan-stats --per-flow --tcp' command incorrectly reports 0 for the TCP TX bytes field even when LAN traffic is active.
  • Page 58 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000550227 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Extension Reported In Release: FOS7.3.0 Technology Area: WAN Performance Analysis Tools Symptom: After running WTOOL tests on FCIP connections between a pair of 7840 switches, BLZ-5024 messages are reported indicating that there was a FCIP DP core panic.
  • Page 59 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000551057 Technical Severity: Medium Probability: Low Product: Brocade Fabric OS Technology: Monitoring Reported In Release: FOS7.4.0 Technology Area: MAPS - Monitoring and Alerting Policy Suite Symptom: "sddquarantine --clear all" clears the SDD port list but "sddquatantine --show" indictaes that it does not delete the local quarantine devices in the device fabric list.
  • Page 60 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000551522 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Extension Reported In Release: FOS7.4.0 Technology Area: FCIP - Tunnel Management Symptom: At the start of non-disruptive firmware download[HCL] on VE ports if there is a Tunnel outage and the tunnel comes online later, it can result in DP-Recovery and all VEs on that DP will be disrupted.
  • Page 61 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000551787 Technical Severity: High Probability: Medium Product: Brocade Fabric OS Technology: Traffic Management Reported In Release: FOS7.4.0 Technology Area: Fibre Channel Routing Symptom: FCR devices not imported for up to 10 minutes following hafailover, resulting in IO disruption. Condition: This may be encountered in an FCR setup, when ports(E/ExVex/Fport) are bounced in edge fabric during hafailover.
  • Page 62 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000552590 Technical Severity: Medium Probability: High Product: Brocade Fabric OS Technology: Security Reported In Release: FOS7.4.0 Technology Area: Zoning Symptom: "zoneshow --validate <zone_name>" without any mode option doesn't validate the enforced zone database.
  • Page 63 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000553920 Technical Severity: Medium Probability: Low Product: Brocade Fabric OS Technology: Management Reported In Release: FOS7.2.1 Technology Area: Virtual Fabrics Symptom: Ports in logical switch may bounce following firmwaredownload or hareboot. Condition: In a VF environment with XISL on and base switch not defined, FMS is enabled on one logical switch, other logical switches without FMS mode enabled, will have FICON filters installed on ports by mistake and cause traffic disruption.
  • Page 64 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000554782 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Management Reported In Release: FOS7.4.0 Technology Area: Software Upgrade Symptom: Unable to download v7.4.0 firmware with unsupported performance monitor configurations on base switch.
  • Page 65 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000555831 Technical Severity: Medium Probability: Medium Product: Brocade Fabric OS Technology: Other Reported In Release: FOS7.3.0 Technology Area: Other Symptom: Memory leak caused weblinker to crash and restart Condition: Various operations such as configupload operation from BNA and LDAP authentication caused memory issue with weblinker.
  • Page 66 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000556188 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Traffic Management Reported In Release: FOS7.4.0 Technology Area: Buffer Credit Management Symptom: On 16G director, while credit recovery feature is not turned on, if there is unstable back-end link, blade could be faulted.
  • Page 67 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000556926 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Distance Reported In Release: FOS8.0.0 Technology Area: FCIP - Fibre Channel over IP Symptom: DP Panics on BR7840 due to memory corruption Condition: This is a rare occurrence from a race condition where TCP Header access occurs after the wire buffer has been freed in IPV6 configuration Defect ID: DEFECT000556929...
  • Page 68 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000557644 Technical Severity: High Probability: Medium Product: Brocade Fabric OS Technology: Traffic Management Reported In Release: FOS7.4.0 Technology Area: FICON Symptom: CUP fails to correctly establish new Reporting Logical Path after receiving Sel Reset Condition: It failed under following conditions during test: 1.
  • Page 69 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000558507 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Distance Reported In Release: FOS7.2.0 Technology Area: FCIP - Fibre Channel over IP Symptom: FX8-24 DP Soft Faults due to SE Core Panic after [FICN-1056] FICON Emulation Error Error Code=7, Condition: Error case when XRC update traffic is running over FCIP XRC Emulation enabled tunnel.
  • Page 70 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000559123 Technical Severity: Medium Probability: Medium Product: Brocade Fabric OS Technology: Extension Reported In Release: FOS8.0.0 Technology Area: WAN Performance Analysis Tools Symptom: Configured WAN Tool session only runs at half the committed rate. Condition: When a WAN Tool session with a committed rate less than 1Gbps is configured, the WAN Tool session will run at half the configured committed rate.
  • Page 71 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000560344 Technical Severity: Medium Probability: Medium Product: Brocade Fabric OS Technology: Other Reported In Release: FOS7.1.1 Technology Area: Other Symptom: Kernel panic while running fcping Condition: This issue is observed rarely when user runs fcping with large frame numbers from different sessions. Defect ID: DEFECT000560375 Technical Severity: High Probability: Low...
  • Page 72 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000560946 Technical Severity: Medium Probability: High Product: Brocade Fabric OS Technology: Extension Reported In Release: FOS7.1.0 Technology Area: Extended Fabrics Symptom: When attempting to form an ISL over an extended fabric link through a third party DWDM, the link does not form.
  • Page 73 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000562107 Technical Severity: High Probability: Low Product: Brocade Fabric OS Technology: Management Reported In Release: FOS7.4.0 Technology Area: Configuration Fundamentals Symptom: iswitch queue full seen in one of the Backbone switches Condition: This is seen when adding zones in a large edge fabric.
  • Page 74 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000563176 Technical Severity: Medium Probability: High Product: Brocade Fabric OS Technology: Traffic Management Reported In Release: FOS7.3.1 Technology Area: Buffer Credit Management Symptom: On a switch where user had manually performed “creditrecovmode --cfg off”, Link Reset will still occur upon detecting credit leak.
  • Page 75 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000563638 Technical Severity: High Probability: Medium Product: Brocade Fabric OS Technology: Distance Reported In Release: FOS7.4.0 Technology Area: FCIP - Fibre Channel over IP Symptom: Observed FICON CHPID IFCCs and job failures. Condition: When FICON Tape Pipelining needs to handle an abnormal sequence such as Attention in REPOSITION_PENDING_STATE.
  • Page 76 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000564981 Technical Severity: Medium Probability: Medium Product: Brocade Fabric OS Technology: Management Reported In Release: FOS7.4.1 Technology Area: Configuration Fundamentals Symptom: A port will never be allowed to be cleared from its quarantined state, if it has been configured to CSCTL mode.
  • Page 77 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000565526 Technical Severity: High Probability: High Product: Brocade Fabric OS Technology: Monitoring Reported In Release: FOS7.4.0 Technology Area: Bottleneck Detection (legacy) Symptom: Automatic credit recovery does not occur but AN-1010 alert is still generated, when all transmit credits of a VC are lost on the 16G side of a 16G to 8G/4G ISL connection.
  • Page 78 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000566644 Technical Severity: Medium Probability: Low Product: Brocade Fabric OS Technology: Traffic Management Reported In Release: FOS7.4.1 Technology Area: Buffer Credit Management Symptom: User may not see the flow metric collected in the AMP. The flow might be dropped at the source switch connecting AMP, since the source switch has QoS mode disabled.
  • Page 79 Defects Closed with Code Change in FOS 7.4.1 Defect ID: DEFECT000568742 Technical Severity: High Probability: High Product: Brocade Fabric OS Technology: Monitoring Reported In Release: FOS7.4.0_AMP Technology Area: MAPS - Monitoring and Alerting Policy Suite Symptom: No space left after files in email delivery spool directory fill up the compact flash Condition: It happens on BR7840 when there is an email failure and error files are not cleaned up automatically by the system.
  • Page 80: Open Defects In Fabric Os V7.4.0

    Open Defects in Fabric OS v7.4.0 This section lists the open defects with Critical, High and Medium Technical Severity as of March 31, 2015 in Fabric OS v7.4.0 Defect ID: DEFECT000455926 Technical Severity: Medium Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.2.0 Technology Area: TIZ - Traffic Isolation Zoning Symptom: Devices outside of fail-over disabled TI zone will have portcam entries if there is an alternative path,...
  • Page 81 Defects Open in FOS 7.4.0 Defect ID: DEFECT000487388 Technical Severity: High Probability: Low Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Flow Vision: Flow Generator Symptom: Some flow generator flows may get deactivated due to system limitations. As a result, they will not generate frames.
  • Page 82 Defects Open in FOS 7.4.0 Defect ID: DEFECT000502603 Technical Severity: Medium Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.3.0 Technology Area: Other Symptom: If “supportsave” command is executed through remote fosexec command, before completion of previously executed “supportsave” command then user may not get the message “supportSave is already running from another connection, please retry later”...
  • Page 83 Defects Open in FOS 7.4.0 Defect ID: DEFECT000509850 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.3.0 Technology Area: Web Tools Symptom: Unable to view the current updated FCIP details after clicking Refresh Now Option. Condition: Changes to the FCIP tunnels in the 7840 platform are not updated in the WebTools views. Workaround: Navigate to another tab and return to see the updated values of FCIP Tunnel.
  • Page 84 Defects Open in FOS 7.4.0 Defect ID: DEFECT000512746 Technical Severity: Medium Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Flow Vision: Flow Monitor Symptom: A WWN based flow will not be deactivated automatically, when the WWN of the generator port is changed using the command 'fapwwn".
  • Page 85 Defects Open in FOS 7.4.0 Defect ID: DEFECT000529293 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.3.1 Technology Area: Ethernet Interface Symptom: IFMODESET command does not change the mode of the interface. Condition: This is seen when the CLI command "ifmodeset" is run in non-interactive mode Workaround: Use interactive mode of this CLI command to set AN or Speed Defect ID: DEFECT000532917 Technical Severity: Medium...
  • Page 86 Defects Open in FOS 7.4.0 Defect ID: DEFECT000537487 Technical Severity: Medium Probability: Medium Product: FOS Technology: Management Reported In Release: FOS7.4.0 Technology Area: Web Tools Symptom: When the IP address is provided for specific logical switch context, the default switch context will be launched.
  • Page 87 Defects Open in FOS 7.4.0 Defect ID: DEFECT000541427 Technical Severity: High Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.0.1 Technology Area: POST - Power-on Self-Test Symptom: switch will panic when the user runs portloopback tests within one hour after hafailover. Condition: This would happen only on C3 platforms.
  • Page 88 Defects Open in FOS 7.4.0 Defect ID: DEFECT000546724 Technical Severity: Medium Probability: Low Product: FOS Technology: FICON Reported In Release: FOS7.4.0 Technology Area: FICON CUP Symptom: Observed " -- FICU_DGB_MSG_001(D) -- Function - ficu_api_deliver_msg_from_remote_CUP() FICU Error RC(-14)" on the console. Condition: Normal switch operation, the message is seen when the IPC system is unable to deliver an IPC message to FICUD.
  • Page 89 Defects Open in FOS 7.4.0 Defect ID: DEFECT000547921 Technical Severity: High Probability: Low Product: FOS Technology: Virtualization Reported In Release: FOS7.3.1 Technology Area: Access Gateway Symptom: In an AG fabric or NPIV environment, device is not found or HBA detects SCSI command timeout and fabric switch stops routing AG switch/NPIV device traffic.
  • Page 90 Defects Open in FOS 7.4.0 Defect ID: DEFECT000548978 Technical Severity: High Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.4.0 Technology Area: Monitoring and Alerting Policy Suite (MAPS) Symptom: During the firmware upgrade from v7.3.0 to v7.4.0, the MAPS Back-End port BAD_OS rule violations are reported for every port in the AP blades (FX8-24).
  • Page 91 Defects Open in FOS 7.4.0 Defect ID: DEFECT000549278 Technical Severity: Medium Probability: High Product: FOS Technology: Distance Reported In Release: FOS7.4.0 Technology Area: FCIP Symptom: The 'portshow lan-stats --per-flow --tcp' command incorrectly reports 0 for the TCP TX bytes field even when LAN traffic is active.
  • Page 92 Defects Open in FOS 7.4.0 Defect ID: DEFECT000549856 Technical Severity: Medium Probability: Low Product: FOS Technology: System Reported In Release: FOS7.4.0 Technology Area: CLI Symptom: When a Quarantined port is moved out of the current Logical Switch, the port is listed as -1/-1 in the output of 'sddquarantine --show' executed in the current Logical Switch Condition: Moving a quarantined port in disabled state to a different Logical Switch in a chassis based switch Workaround: Remove the port from quarantined state using sddquarantine --clear <slot/port>...
  • Page 93 Defects Open in FOS 7.4.0 Defect ID: DEFECT000550554 Technical Severity: Medium Probability: Low Product: FOS Technology: FICON Reported In Release: FOS7.4.0 Technology Area: FICON CUP Symptom: With CUP Diagnostics and zOS HealthChecker, a port that reports a SlowDrain or Bottleneck Detected event, may persist in reporting this state, even though the condition has cleared.
  • Page 94 Defects Open in FOS 7.4.0 Defect ID: DEFECT000551522 Technical Severity: High Probability: Low Product: FOS Technology: Distance Reported In Release: FOS7.4.0 Technology Area: Tunnel Management Symptom: At the start of non-disruptive firmware download[HCL] on VE ports if there is a Tunnel outage and the tunnel comes online later, it can result in DP-Recovery and all VEs on that DP will be disrupted.
  • Page 95: Closed With Code Change In Fabric Os V7.4.0

    Closed with Code Change in Fabric OS v7.4.0 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of March 31, 2015 in Fabric OS v7.4.0. Defect ID: DEFECT000417089 Technical Severity: Medium Probability: Medium Product: FOS Technology: Security...
  • Page 96 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000457373 Technical Severity: High Probability: High Product: FOS Technology: Virtualization Reported In Release: FOS7.0.2 Technology Area: Access Gateway Symptom: BR5480 embedded switch displays invalid message without functional impact. Condition: Invalid message "Request F-N Port Mappings for Access Gateway Change from SW" is observed while running in native switch mode.
  • Page 97 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000483437 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Web Tools Symptom: On Web Tools, the cascaded switch Icon in Fabric Tree gets greyed out and the pop up shows the status as "Unmonitored".
  • Page 98 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000488832 Technical Severity: High Probability: Low Product: FOS Technology: Virtualization Reported In Release: FOS7.1.1 Technology Area: Virtual Fabrics Symptom: During testing, embedded switch intermittently fails after reboot. Condition: After high reboot count, with less than 127 targets, switch will occasionally not respond to name server queries.
  • Page 99 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000493407 Technical Severity: Medium Probability: Medium Product: FOS Technology: Management Reported In Release: FOS7.3.0 Technology Area: SNMPv2, SNMPv3 & MIBs Symptom: By default FOS SNMP will allow SNMP v1/v3 SET operation. Condition: FOS SNMP write access is enabled by default.
  • Page 100 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000499012 Technical Severity: High Probability: Medium Product: FOS Technology: Management Reported In Release: FOS7.3.0 Technology Area: Platform Services Symptom: Unable to stop the autoboot using the ESC key to get into command shell. Condition: This is encountered during boot up, where the escape sequence key is not functioning properly.
  • Page 101 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000500085 Technical Severity: Medium Probability: Medium Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: NTP - Network Time Protocol Symptom: Switches in the fabric are unable to communicate with the NTP server. Condition: When the BR5647 is insert into the embedded chassis or when the chassis CMM is rebooted, the CMM will push the NTP network configuration for internal communication to external fabric wide.
  • Page 102 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000501658 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.0.1 Technology Area: NTP - Network Time Protocol Symptom: Switch panics after time server daemon failed to sync time with server. Condition: This may occur from an Ethernet network issue in the fabric resulting in a failure to resolve DNS names into IP addresses.
  • Page 103 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000504254 Technical Severity: High Probability: Low Product: FOS Technology: Other Reported In Release: FOS7.1.1 Technology Area: Other Symptom: Intermittent systemverification failures may be encountered when the number of test runs are increased to 50 or more.
  • Page 104 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000505940 Technical Severity: Medium Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.3.0 Technology Area: Other Symptom: Ambigous eError message when removing 7840 WAN Rate Upgrade 2 license using WebTools and there IP interface configured.
  • Page 105 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000509898 Technical Severity: Medium Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.3.0 Technology Area: Other Symptom: Switchshow and portcfgshow displays ports configuration as "Auto Negotiate" when configured as fixed speed after firmeare download to FOS 7.3.0 Condition: After a firmware download to FOS v7.3.0 from previous release, switchshow and portcfgshow displays port configuration as auto negotiate when configured as fixed speed.
  • Page 106 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000512293 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.3.0 Technology Area: Ethernet Interface Symptom: For 7840 platform, the management link doesn't come up when eth0 (Magament inteface) speed and duplex is forced to 100Mbps/Half-duplex and rolling error message seen on console.
  • Page 107 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000513544 Technical Severity: High Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.1 Technology Area: Management Server Symptom: During code upgrade, standby CP may run into repeated msd panics and may not come online to standby ready mode.
  • Page 108 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000513923 Technical Severity: High Probability: High Product: FOS Technology: Virtualization Reported In Release: FOS7.2.0 Technology Area: Access Gateway Symptom: ELS commands get rejected and host on AG switch can no longer communicate with the target in the 3rd party vendor fabric.
  • Page 109 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000515227 Technical Severity: Medium Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.3.0 Technology Area: Other Symptom: After HA reboot, customer will not be able to see the enforced authentication details information in EX-port.
  • Page 110 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000516255 Technical Severity: High Probability: Low Product: FOS Technology: Distance Reported In Release: FOS7.3.0 Technology Area: FCIP Symptom: Any replication devices using ELS (PRLI) and ELS _ACC frames as heartbeat during the replication might have potential traffic disrupted when doing non-disruptive firmwaredownload in FCR configuration.
  • Page 111 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000516632 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.3.0 Technology Area: CLI Symptom: Userspace daemon mdd may crash after an extended period. This incident is benign since the daemon is automatically restarted Condition: This is a rare occurrence resulting from a very slow memory leak in L2 device monitoring.
  • Page 112 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000519313 Technical Severity: Medium Probability: Medium Product: FOS Technology: Virtualization Reported In Release: FOS7.0.2 Technology Area: Access Gateway Symptom: Internal ports may not be properly enabled or disabled after boot-up. Condition: This may be encountered on a very busy system, where expansion commands from SVP may not get processed in time.
  • Page 113 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000520219 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Monitoring and Alerting Policy Suite (MAPS) Symptom: customer cannot achieve Port Decom even though that action is configured in the rule Condition: This is encountered if Port Fence and Port Decom are the only actions configured in the rule Defect ID: DEFECT000520549...
  • Page 114 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000521195 Technical Severity: High Probability: Medium Product: FOS Technology: FICON Reported In Release: FOS7.2.0 Technology Area: FICON Symptom: Add ability to enable insistent domain ID (IDID) while the switch is online to permit non-disruptive upgrade v7.2.x to v7.3.
  • Page 115 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000522361 Technical Severity: High Probability: Low Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.1.0 Technology Area: Monitoring and Alerting Policy Suite (MAPS) Symptom: 16Gbs Core blades experiencing heavy frame loss are not being faulted and impacted fabric traffic. Condition: When 16G blades experience excessive bad_os, enc_out etc link errors Recovery: Replace excessive link error blade.
  • Page 116 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000523092 Technical Severity: Medium Probability: High Product: FOS Technology: System Reported In Release: FOS7.3.0 Technology Area: CLI Symptom: Unable to collect supportsave on BR5460 with error msg: “The switch does not have enough disk space to run full supportSave.
  • Page 117 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000523530 Technical Severity: Medium Probability: High Product: FOS Technology: Security Reported In Release: FOS7.1.1 Technology Area: Encryption Symptom: On LUN expansion, hosts showed the disk space as “un-allocated” Condition: The problem may be encountered in encryption environment (BES/FS8-18) when slow path and control frames are punted to software.
  • Page 118 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000524177 Technical Severity: High Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Flow Vision: Flow Monitor Symptom: Creating and activating flow monitor on inflight encryption and compression enabled ports is not blocked Condition: Flow monitoring is not supported on inflight encryption and compression enabled ports.
  • Page 119 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000525347 Technical Severity: Medium Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.0.2 Technology Area: FC-FC routing Symptom: Customer may observe performance issues between multiple servers and storage with EX-port connected to VDX Condition: This may occur when there are link level errors that trigger credit loss on 16G EX port and there was prior HA warm recovery that disabled credit leak detection.
  • Page 120 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000526158 Technical Severity: Medium Probability: High Product: FOS Technology: Other Reported In Release: FOS7.0.2 Technology Area: Other Symptom: Customer may observe increasing er_crc_good_eof and er_enc_in errors on backend ports, leading to performance problems.
  • Page 121 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000526819 Technical Severity: High Probability: High Product: FOS Technology: FICON Reported In Release: FOS7.3.0 Technology Area: FICON CUP Symptom: "Detected term of ficucd" kernal panic while running CUP Condition: Running heavy FICON CUP test traffic creates a Diags Query CCW for the CUP it is connected to, at the same time that an IDC Query message arrives from another CUP, that is also attached to a CHP running test traffic.
  • Page 122 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000527506 Technical Severity: High Probability: Medium Product: FOS Technology: System Reported In Release: FOS7.1.0 Technology Area: Component Symptom: I2C access failures leading to various symptoms such as: 1. slotshow command output may flag some components with an "*", indicating no i2c access to that component.
  • Page 123 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000528010 Technical Severity: High Probability: High Product: FOS Technology: Distance Reported In Release: FOS7.3.0 Technology Area: FCIP Symptom: FCIP HCL failure encountered due to a large number of FCIP objects in the configuration Condition: This is encountered when a large number of FCIP Objects (>>...
  • Page 124 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000528657 Technical Severity: Medium Probability: Medium Product: FOS Technology: Traffic Management Reported In Release: FOS7.2.0 Technology Area: Name Server / Zoning Symptom: FCPD termination encountered when device sends malformed response with incorrect R_CTL information during FCP probing Condition: This occurs only when the device reponds with malformed frames during FCP probing Defect ID: DEFECT000528728...
  • Page 125 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000531192 Technical Severity: High Probability: Medium Product: FOS Technology: FICON Reported In Release: FOS7.2.0 Technology Area: FICON CUP Symptom: During firmware upgrade, hosts lost paths due to FICON filter that was not properly cleaned up. Condition: On a FMS CUP enabled switch, if trunk master goes offline first, after hafailover FICON CUP filter is not properly removed.
  • Page 126 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000532108 Technical Severity: Medium Probability: Medium Product: FOS Technology: Security Reported In Release: FOS6.4.3_dcb Technology Area: Security Vulnerability Symptom: Security vulnerability CVE-2014-3566 makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack.
  • Page 127 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000532888 Technical Severity: Medium Probability: Medium Product: FOS Technology: FICON Reported In Release: FOS7.1.0 Technology Area: FICON emulation Symptom: I/O Errors to FICON extended device over an FCIP Tunnel with FICON Emulation features enabled. Condition: When running FICON channel programs to an extended device that includes Repeat Execution CCW commands (typically used in Disk I/O channel programs).
  • Page 128 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000534413 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.2.1 Technology Area: Monitoring and Alerting Policy Suite (MAPS) Symptom: "logicalgroup --show" command will show more ports than switch has under "ALL_PORTS" group.
  • Page 129 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000537093 Technical Severity: High Probability: High Product: FOS Technology: Distance Reported In Release: FOS7.1.1 Technology Area: OSTP - Open Systems Tape Pipelining Symptom: Timeouts after Reservation Conflict Status with tape devices when Fastwrite and Tape-pipelining are enabled Condition: This occurs when multiple servers attempt to reserve the same tape device over OSTP enabled tunnel.
  • Page 130 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000538092 Technical Severity: Medium Probability: Low Product: FOS Technology: Virtualization Reported In Release: FOS7.2.1 Technology Area: Access Gateway Symptom: Following a FOS firmware upgrade or hareboot, traffic to and from the Access Gateway stops after the N-Port trunk master is disabled.
  • Page 131 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000539576 Technical Severity: High Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.2.1 Technology Area: supportShow Symptom: TRCE-1005 will be triggerd when autoftp feature is enabled with SCP protocol. Condition: Happens only on systems configured with SCP protocol.
  • Page 132 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000540585 Technical Severity: High Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.2.1 Technology Area: supportShow Symptom: Support Save output does not include VE or GE port information Condition: This is seen after multiple logical switches have been created and one or more of the logical switches have been deleted and the VE ports reside in a logical switch that was created after one that was deleted.
  • Page 133 Defects Closed with Code Change in FOS 7.4.0 Defect ID: DEFECT000543727 Technical Severity: Low Probability: Low Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Logging Symptom: The CP flash drive can run low on space due to the /var/log/esmd_lib.log file growing too large. Condition: The problem may occur on any switch other than the Brocade 7840 switch, when running with FOS7.3.0x and FOS7.3.1.
  • Page 134: Closed Without Code Change In Fabric Os V7.4.0

    Closed without Code Change in Fabric OS v7.4.0 This section lists the defects with Critical, High and Medium Technical Severity closed without a code change as of March 31, 2015 in Fabric OS v7.4.0 Defect ID: DEFECT000395600 Technical Severity: High Probability: Low Product: FOS Technology: Other...
  • Page 135: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000482787 Technical Severity: Medium Probability: Low Product: FOS Technology: Virtualization Reported In Release: FOS6.2.2 Technology Area: Access Gateway Symptom: Sometimes F-Port failover is not working on Access Gateway switch. Condition: On a switch running FOS v6.2.2x in Access Gateway mode: - Configure two N_ports (ports 17 and 18) - Map F_ports 1, 2, 3, 4 0 to Nport 18 - Map F_ports 5, 6, 7, 8 to Nport 17...
  • Page 136: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000498502 Technical Severity: Medium Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Flow Vision: Flow Generator Symptom: When user creates a WWN flow with a SID/DID and also creates a PID flow with same SID/DID while the DID is offline, both the flows would be activated but not enforced.
  • Page 137: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000512005 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Platform Services Symptom: "disable external ports" followed by "enable external ports" on embedded switch CMM interface (GUI or CLI), leads to changing external port speed from Auto Negotiate to 16Gb fixed.
  • Page 138: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000513776 Technical Severity: High Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.3.0 Technology Area: Other Symptom: Name Server (NS) queue full condition leads to NS out of sync with local/remote devices and the device connectivity info will become inconsistent.
  • Page 139: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000521209 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: POST - Power-on Self-Test Symptom: POST tests do not run as expected using CMM. Condition: Issue happens when POST tests are verified through CMM on embedded switches.
  • Page 140: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000527025 Technical Severity: Medium Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: APM - Advanced Performance Monitoring Symptom: CLI command fmmonitor --delmonitor <fmtype> -port 2/2 returns with "Specified Frame type doesn't exist on the specified port"...
  • Page 141: Fabric Os 7.4.1A Release Notes V3.0

    Defects Closed without Code Change in FOS 7.4.0 Defect ID: DEFECT000532529 Technical Severity: Medium Probability: Medium Product: FOS Technology: System Reported In Release: FOS6.4.3_dcb Technology Area: Component Symptom: Switch detected sshmd panic after experience PCI abort error with FCOE switch with raslog [EANV- 1006] and fail over application did not kick in caused fabric disruption.
  • Page 142 Defects Closed without Code Change in FOS 7.4.0 Condition: This is encountered when LOS area systemmonitor is configured as pause, and switch status policy is configured as based on port class. Defect ID: DEFECT000540638 Technical Severity: Medium Probability: Medium Product: FOS Technology: System Reported In Release: FOS6.4.3 Technology Area: Component...