Defect ID: DEFECT000521195
Technical Severity: High
Product: FOS
Reported In Release: FOS7.2.0
Symptom: Add ability to enable insistent domain ID (IDID) while the switch is online to permit non-disruptive
upgrade v7.2.x to v7.3.
Condition: As per design, upgrade to from FOS7.2.x to FOS v7.3 is blocked if customer has single switch fabric
in FMS mode with SCC policy configured but IDID OFF. It requires a "switchdisable" in FOS v7.2.x
to set IDID ON.
Defect ID: DEFECT000521218
Technical Severity: High
Product: FOS
Reported In Release: FOS7.3.0
Symptom: Host discovery issues after upgrade to FOS7.2.x in FC Routed configuration over VE/VEX ports
Condition: These host discovery issues may be encountered following upgrade to any FOS7.2.x release from a
FOS version prior to FOS7.2.0, in FC Routed configuration over VE/VEX ports
Workaround: Downgrade to a FOS release prior to FOS7.2.0.
Defect ID: DEFECT000521272
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.2.1
Symptom: FW-1430 raslog messages logged to indicate possible faulty temperature sensor, but with no
subsequent FW-1003 messages to indicate which sensor is triggering the alarms.
Condition: This may be encountered if the sensor issue is transient in nature and problem recovers before
triggering subsequent faults.
Defect ID: DEFECT000521398
Technical Severity: High
Product: FOS
Reported In Release: FOS7.1.1
Symptom: Before shutdown switch due to a high temperature alert, emd encountered an assert and caused switch
to panic.
Condition: This may happen during switch shutdown following a high temperature warning "Unit will be shut
down in 2 minutes if temperature remains high"
Defect ID: DEFECT000521981
Technical Severity: High
Product: FOS
Reported In Release: FOS7.3.0
Symptom: Defined flows on the master port are deleted
Condition: Deactivate and delete defined flows on a slave port will delete flows on the master port.
Fabric OS 7.4.1a Release Notes v3.0
Defects Closed with Code Change in FOS 7.4.0
Probability: Medium
Technology: FICON
Technology Area: FICON
Probability: Medium
Technology: Distance
Technology Area: Extended Fabrics
Probability: High
Technology: Monitoring/RAS
Technology Area: Fabric Watch
Probability: Low
Technology: Monitoring/RAS
Technology Area: Equipment Status
Probability: Medium
Technology: Monitoring/RAS
Technology Area: Flow Vision: Flow Monitor