Defect ID: DEFECT000521209
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.3.0
Symptom: POST tests do not run as expected using CMM.
Condition: Issue happens when POST tests are verified through CMM on embedded switches.
Defect ID: DEFECT000521344
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.1.2
Symptom: Configuring porthconfig with area ST posts continuous alerts even after being in the same state.
Condition: Configure ST area for portclasses(port/eport/fport/fcuport classes)
Defect ID: DEFECT000523507
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.1.2
Symptom: Fabric Watch ST area of SFP class does not change to "pause" when executing CLI " thconfig --pause
sfp -area all -port all" or gives any error to indicate that it's not supported.
Condition: The issue is seen only when the ST area option is used with SFP class. ST is already deprecated in
FOS v7.0.0 and no longer supported.
Defect ID: DEFECT000523910
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.3.0
Symptom: Debug messages appear on the console during portloopbacktest on a 16G platform.
Condition: Portloopbacktest with default options from command line will result in debug messages displayed
that has no impact to functionality
Defect ID: DEFECT000524476
Technical Severity: High
Product: FOS
Reported In Release: FOS7.3.0
Symptom: Unable to view switch partitions and their port details through BNA.
Condition: A logical switch having more than 256 ports, not including ICLs, that show the "No area available for
PID assignment" message in switchshow.
Defect ID: DEFECT000526298
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.1.2
Symptom: Event values that occur when portthconfig --pause is used are displayed after portthconfig --continue
is executed.
Condition: When a port is paused for certain class and area and enabled later it still has the previous values
which it had during pause.

Fabric OS 7.4.1a Release Notes v3.0

Defects Closed without Code Change in FOS 7.4.0
Probability: High
Technology: Monitoring/RAS
Technology Area: POST - Power-on Self-Test
Probability: Medium
Technology: Monitoring/RAS
Technology Area: Fabric Watch
Probability: Medium
Technology: Monitoring/RAS
Technology Area: Fabric Watch
Probability: High
Technology: Other
Technology Area: Other
Probability: Medium
Technology: FICON
Technology Area: FICON
Probability: High
Technology: Monitoring/RAS
Technology Area: Fabric Watch