5. Operation
Off
Shutting down
Off
Antifreeze mode
5.7

Switching Off the Fuel Cell

Press
device.
The unit will gradually shut down, performing various
function checks as it does so:
To protect components, the unit must run at least 30
minutes before shutting down. If the unit is shut off
beforehand, it will continue running until 30 minutes
have elapsed. The message "Shutting down" will
appear in the display. Leave the fuel cartridge and the
battery connected during this time.
5.8

Automatic Antifreeze Feature

This unit features an intelligent antifreeze feature. The
unit can keep itself warm at temperatures below 3° C
as long as it is connected to a working battery and it is
supplied with methanol.
If the unit is in antifreeze mode, the message
"Antifreeze mode" will appear on the second line. The
first line will indicate the current operating mode, for
example "Off".
The antifreeze function works only as long as a fuel
cartridge and a sufficiently charged battery are
connected.
The unit will not be able to start if the battery voltage
falls below 10.5 volts. Please note that the unit will not
recharge the battery if the voltage drops below 10.5
volts.