Performance
Product
Rating
Charge capacity
Nominal voltage
Charging current @ 12 V
Turn on threshold*
Cut off threshold*
Required starting voltage
Quiescent current requirement 15 mA
Methanol requirement
Compatible batteries
General Specifications
Sound pressure level at 7 m
Dimensions (L x W x H)
Weight
Environmental conditions
Space requirement (L x W x H) 51 x 35 x 30 cm minimum
Inclination along the direct
axis
Inclination along the
quadrature axis
Operating temperature
Start temperature
Storage temperature
* factory setting
3.4

Specifications

EFOY 600
25 W
600 Wh/Day
(50 Ah/Day)
12 V
2.1 A
U
< 12.5 V
batt
U
>14.2 V and
batt
I
< 2.0 A
out
> 10.8 V
1.1 l/kWh
12 V rechargeable (lead-acid or lead-gel) batteries with 40 to
200 Ah capacity
23 dB(A)
43.5 x 20 x 27.6 cm
7.5 kg
continual:
temporary (<10 min):
continual:
-20 to +40 °C
+5 to +40 °C
+1 to +45 °C
EFOY 1200
50 W
1200 Wh/Day
(100 Ah/Day)
12 V
4.2 A
U
< 12.5 V
batt
U
>14.2 V and
batt
I
< 2.0 A
out
> 10.8 V
15 mA
1.1 l/kWh
35°
45°
20°
11
EFOY 1600
65 W
1600 Wh/Day
(130 Ah/Day)
12 V
5.4 A
U
< 12.5 V
batt
U
>14.2 V and
batt
I
< 2.0 A
out
> 10.8 V
15 mA
1.1 l/kWh

Advertisement

Table of Contents
loading

This manual is also suitable for:

12001600