5. Operation
On
Charging mode
Automatic
Voltage 13.6 V
Automatic
4.6 A
5.3

Switching on the Fuel Cell

If desired, you can switch on the unit manually
regardless of the battery voltage. The unit will then be
in the "charging mode".
This function is only possible when the battery voltage
is below 13.2V
Press
switched off, and twice if it is operating in automatic
mode. The unit will start up regardless of the battery
voltage and will continue charging until it reaches the
cutoff point
(U
>14,2 V und I
batt
The device will then switch to automatic mode by itself
and will only charge if the battery or the demand for
power requires it.
5.4

Display Information

The second line of the display provides information
about normal operation, errors or malfunctions (see
Chapter 7). The first line indicates the operating mode
selected, such as "Automatic".
Press >> to obtain the following information.
Battery voltage
Charging current
Please note that the device interrupts power generation
briefly several times an hour during normal operation
and a charging power of 0.0 A is displayed then.
35
on the control panel once if the unit has been
< 2,0 A).
out