Operation; 38Ap 50 Hz Additional Lubricant (Si); Time, Day, And Date; Time/Date Broadcast - Carrier 38APS025 Manual

Gemini select, commercial air-cooled condensing units with comfortlink version 6.x controls 50/60 hz
Table of Contents

Advertisement

UNIT SIZE
CIRCUIT
UP to 7.5 m
A
38APD025
B
38APS025
Single
A
38APD027
B
38APS027
Single
A
38APD030
B
38APS030
Single
A
38APD040
B
38APS040
Single
A
38APD050
B
38APS050
Single
A
38APD060
B
38APS065
Single
A
38APD070
B
A
38APD080
B
A
38APD090
B
A
38APD100
B
A
38APD115
B
A
38APD130
B
1261

OPERATION

Time, Day, and Date —
controls require that the time, day and date be properly set.
This is especially helpful when troubleshooting alarms, as they
are reported with a time and date stamp. ComfortLink controls
also have the ability to automatically adjust for daylight sav-
ings time, when configured. The unit time and date is set at the
factory based in the Eastern Time Zone.
To set the time, Time Clock TIME HH.MM (Hour and
Minute) is the item. The time clock is programmed in a 24-
hour format, 00.00 to 23.59. See Table 16.
To set the month, Time Clock DATE MNTH (Month)
is the item. This item follows the standard convention, 1=Janu-
ary, 2=February, etc.
To set the day of the month, Time Clock DATE DOM
(Day of Month) is the item.
To set the day of the week, Time Clock DATE DAY
(Day of Week) is the item. This item uses the following con-
vention: 1=Monday, 2=Tuesday, 3=Wednesday, etc. This set-
ting is important if using the internal schedule.
To set the year, Time Clock DATE YEAR (Year of Cen-
tury) is the item. This item follows the convention of a 4-digit
year, such as 2014.
Table 17 lists the required configurations for these settings.
Table 15 — 38AP 50 Hz Additional Lubricant (SI)
ADDITIONAL LUBRICANT (mL) ESTIMATE FOR PIPING LENGTH AND REFRIGERANT
7.5 to 15 m
15 to 22.5 m
0
0
0
0
298
364
396
0
0
185
0
0
185
323
388
421
0
0
194
0
0
194
361
426
563
261
326
359
0
277
309
693
886
983
274
339
371
323
388
421
852
1046
1142
336
401
433
361
426
563
977
1170
1267
361
426
563
586
779
876
361
426
563
817
1010
1107
693
886
983
817
1010
1107
852
1046
1142
817
1010
1107
817
1010
1107
977
1170
1267
817
1010
1107
1590
1755
Many features of the 38AP
22.5 to 30 m
30 to 37.5 m
0
200
223
0
200
223
429
637
209
232
209
232
594
661
217
241
217
241
631
699
391
424
342
374
1079
1176
404
612
594
661
1239
1336
606
674
631
699
1636
1801
631
699
973
1069
631
699
1203
1641
1079
1176
1203
1300
1239
1336
1203
1300
1203
1300
1636
1801
1203
1300
1920
2085
TIME/DATE BROADCAST — The 38AP unit controls have
the ability to broadcast the time and date on the network. If the
CCN
Time/Date
tion BCST T.D.BC=ON, the control will send the time and
date out onto the CCN bus once a minute. If this device is on a
CCN network, it is important to make sure that only one
device on the bus has this configuration set to ON. If more
than one time broadcaster is present, problems with the time
will occur. If the unit is installed on a network, another unit
must be configured to be Broadcast Acknowledger, Configu-
ration BCST BC.AK. Only one unit can be the Broadcast
Acknowledger. See Table 18 for required configurations.
DAYLIGHT SAVINGS TIME — The 38AP controls have
the ability to automatically adjust the time for daylight savings
time. To utilize this feature, several items must be configured,
including a start date and time to add as well as an end date.
All items are found in the Daylight Saving Time sub-mode,
Time Clock DST and the Broadcast sub-mode, Configura-
tion BCST. See Table 19 for required configurations.
NOTE: Only the time and date broadcaster can perform day-
light savings time adjustments. Even if the unit is stand-alone,
the user may want to set Configuration BCST T.D.BC to
ON to accomplish the daylight savings function. To disable the
daylight savings time feature, set T.D.BC to OFF.
59
37.5 to 45 m
45 to 52.5 m
246
270
246
270
704
772
255
278
255
278
729
797
264
287
264
287
766
834
457
735
407
685
1272
1369
679
747
729
797
1841
2006
742
809
766
834
1965
2130
766
834
1166
1262
766
834
1805
1970
1272
1369
1805
1970
1841
2006
1805
1970
1805
1970
1965
2130
1805
1970
2249
2414
Broadcast
configuration
52.5 to 60 m
293
293
840
302
302
864
311
311
902
802
752
1466
815
864
2170
877
902
2984
902
1359
902
2135
1466
2135
2170
2135
2135
2295
2135
3268
Configura-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents